Installation

Compressor Wiring

Wiring
Compressor
Compressor
Wiring
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
Follow these instructions to wire Graco Compressor
24Y544 (120V) or 24Y545 (240V).
NOTE: Use only copper wire with an insulation rating
NOTE:
NOTE:
of 75°C or higher.
1. Remove the cover from the compressor's
electrical box.
Figure 10
KEY
KEY
KEY
A A A To power supply
18
All manuals and user guides at all-guides.com
2. Install wiring system with proper connections (i.e.
3. Connect line power (120VAC or 240 VAC,
4. Reinstall the cover of the electrical box. Torque
L2
L1
conduit/fittings, power cable/cable grip) to the
compressor electrical box.
depending on your compressor) to L1 and L2/N.
Connect supply ground to
12 AWG (4 mm
2
) wire when the system is
configured for a 16A circuit and 14 AWG (2.5
mm
2
) when configured for a 12A circuit. Torque
terminals to 10 in-lb (1.2 N•m).
screws to 60 in-lb (6.8 N•m).
. Use minimum