4 - PRODUCT INSTALLATION

4.1 - Installation

ù
Before proceeding with the installation, check the integrity of the
product and that all components are present in the package.
Also make sure that the mounting area of the gear motor is compat-
ible with the dimensions (Fig.1).
Ensure that leaf travel is limited, on opening and closing, by mecha-
nical stops securely anchored to the ground.
Check the permitted opening angle, based on the mounting points of
the brackets with the graph (Fig.4).
Fig.3 shows a typical installation:
- Gear motors
- Photocells
- Columns for photocells
- Flashing light with antenna
- Key switch or digital keypad
- Control unit
Installing the rear fixing bracket
The fixing position of the rear bracket is determined according to the
graph (Fig. 4).
Important: installations where the values of "A" and "B" (Fig. 5) are
as similar to each other as possible are preferred.
If necessary, cut the rear bracket (Fig. 6) to obtain the value "B", then
weld the fixing bracket to the wall.
Secure the bracket to the wall using welding, screws or bolts (not
included).

4.2 - Electrical connections

Insert the supply cable to the terminal. Connect the wires of the supply cable to the terminal following the electrical drawing in Fig. 9.
Installing the front fixing bracket
The front bracket must be fixed to the door according to dimension
"E" (Fig.5).
Installing the gear motor
Place the gear motor against the rear bracket and insert the fixing
screw.
Insert the pin of the sliding bracket into the bush of the front bracket
and secure it with the screw and washer provided.
Tighten the screw on the rear bracket previously mounted with the
nut.
After the installing operations, release the operator and ensure that
the gate opens smoothly with no stiff points and that it stops on the
mechanical travel stops obtaining the leaf openings determined by
the fitting position of the operator with reference to Fig. 4.
ATTENZIONE !
Do not exceed the leaf opening determined by the fitting posi-
tion of the operator with reference to Fig. 4, otherwise the ope-
rator may be irreversibly damaged!