ERVER 5013S-8/5013S-i Manual
VGA Enable/Disable
JP9 allows you to enable or dis-
able the VGA port.
position is on pins 1 and 2 to en-
able VGA.
See the table on the
right for jumper settings.
Fan Status Select
JP15 allows you to change the sta-
tus of the Overheat/Chassis fan to
either activate only during an over-
heat condition (set in BIOS) or to
reamin active at all times. The de-
fault position is open. See the table
on the right for jumper settings.
Watch Dog Enable/Disable
JP19 is used to enable or disable
the Watch Dog function.
jumper is used together with the
Watch Dog enable function in
BIOS. Enable both the jumper and
the BIOS setting to use the Watch
Dog feature. See the table on the
right for pin definitions.
Mb LAN Enable/Disable
Change the setting of jumper JP10
to enable or disable the Mb LAN
port on the motherboard. See the
table on the right for jumper set-
tings.
The default setting is pins
1-2.
The default
This
5-22
VGA Enable/Disable
Jumper Settings
(JP9)
Jum per
Position
Definition
1-2
Enabled
2-3
Disabled
Fan Status Select
Jumper Settings (JP15)
Jum per
Position
Definition
Open
Overheat
Closed
Alw ays On
W atch Dog Enable/
Disable
Jumper Settings (JP19)
Jumper
Position
Definition
Open
Disabled
Closed
Enabled
M b LAN
Enable/Disable
Jumper Settings
(JP10)
Jum per
Position
Definition
Pins 1-2
Enabled
Pins 2-3
Disabled