Advertisement

Quick Links

KALEIDO VP
KALEIDO
VP
120 - 170 - 220 - AE45
H117 - H135
EN
Use and Maintenance Manual
ISA S.r.l.
Via del Lavoro, 5
06083 Bastia Umbra - Perugia - Italy
Tel. +39 075 80171 - Fax +39 075 8000900
www.isaitaly.com
EN
1
428000346037

Advertisement

Table of Contents
loading

Summary of Contents for ISA KALEIDO VP

  • Page 1 KALEIDO VP KALEIDO 120 - 170 - 220 - AE45 H117 - H135 Use and Maintenance Manual ISA S.r.l. Via del Lavoro, 5 06083 Bastia Umbra - Perugia - Italy Tel. +39 075 80171 - Fax +39 075 8000900 www.isaitaly.com...
  • Page 2 KALEIDO VP 428000346037...
  • Page 3: Table Of Contents

    KALEIDO VP INDEX 9. CUSTOMER SUPPORT CENTRE ..24 1. NOTES / IMPORTANT NOTES ..4 1.1 Introduction ....5 9.1 Faults...
  • Page 4: Notes / Important Notes

    KALEIDO VP 1. NOTES / IMPORTANT NOTES The content of this manual is of a technical nature and is owned by ISA S.r.l. It is forbidden to reproduce, circulate or modify all or part of its content without written consent.
  • Page 5: Introduction

    KALEIDO VP 1.1 Introduction ISA S.r.l. employs materials of the best quality and as they enter the company, we constantly monitor their storage and the use as part of the manufacturing process to prevent damage, deterioration and failure. All manufacturing elements are designed and manufactured in order to guarantee reliability and high safety standards.
  • Page 6: Safety Standards Contained In The Manual

    KALEIDO VP 1.3 Safety standards contained in the manual The safety requirements, indications, standards and notes illustrated in the various chapters of the manual are aimed at establishing a code of conduct and a series of obligations to be observed when performing the various activities, in order to create safe conditions for personnel, the equipment and the surrounding environment.
  • Page 7: Technical Specifications And Dimensions

    KALEIDO VP 2. TECHNICAL SPECIFICATIONS AND DIMENSIONS This refrigerated cabinet is exclusively intended to display and sell fresh pastry. The manufacturer is not liable for injury to persons or damage to property or the cabinet itself caused by the displaying of products other than those described above.
  • Page 8: Load Limits

    KALEIDO VP 2.1 Load limits WARNING IT IS ESSENTIAL NOT TO OVERLOAD THE APPLIANCE IN ORDER TO PREVENT ANY ALTERATION TO THE CORRECT AIR FLOW AND THEREFORE PREVENT HIGHER PRODUCT TEMPERATURES. 2.2 Positioning / Leveling WARNING THIS REFRIGERATED CABINET IS FITTED WITH ADJUSTABLE FEET IS ABSOLUTELY NECESSARY AFTER PLACEMENT TO STABILIZE THE CABINET ADJUSTING THE FEET LIKE SHOWED IN THE PICTURE.
  • Page 9: Cabinet Description

    KALEIDO VP 3. CABINET DESCRIPTION 3.1 General description and operating principles To ensure the operator’s safety, the refrigerated cabinet’s devices should be kept constantly effi cient. This manual has the purpose of illustrating the use and maintenance of the cabinet.
  • Page 10: Safety

    KALEIDO VP 4. SAFETY 4.1 General information The buyer is responsible for training personnel using the appliance on the risks, security devices and general health and safety rules required by the laws where the refrigerated cabinet is installed. Users/operators should be aware of the position of all the controls and how they work, as well as of the features of the refrigerated cabinet.
  • Page 11: Identifi Cation

    KALEIDO VP 4.1.2 Identifi cation Symbols of compliance Manufacturer’s address Production Order Type Model Name Article Serial Number Production date 9 - 10 Power Supply Voltage and frequency Gross capacity Absorption at Rated capacity Absorption during defrosting Absorption of heating Elements...
  • Page 12: Waste Disposal

    KALEIDO VP 4.2 Waste disposal During its normal operations, the refrigerated cabinet does not generate any environmental contamination. At the end of its life cycle, or if it is necessary to proceed to defi nitive decommissioning, we recommend following the procedures below:...
  • Page 13: Safety Devices Applied To The Refrigerated Cabinet

    KALEIDO VP 4.3 Safety devices applied to the Refrigerated cabinet The refrigerated cabinet is equipped with the safety devices below: SAFETY DEVICES FITTED ON THE REFRIGERATED CABINET FIXED PROTECTIVE DEVICES SECTIONING THE ELECTRICAL POWER SUPPLY 4.3.1 Fixed protective devices Fixed protections consist of fi xed perimeter shields, which are used to prevent external parts from entering inside the refrigerated cabinet.
  • Page 14: Residual Risks

    KALEIDO VP 4.4 Residual risks during design the manufacturer examined all the areas or parts at risk. Therefore, all necessary precautions have been taken to prevent risks to persons and damage to the refrigerated cabinet as mentioned earlier. WARNING PERIODICALLY CHECK THAT ALL SAFETY DEVICES ARE OPERATING CORRECTLY.DO NOT REMOVE THE FIXED PROTECTIVE DEVICES FROM THE REFRIGERATED CABINET.DO NOT INTRODUCE FOREIGN...
  • Page 15: Explosive Atmosphere

    4.5 Warning signs (if any) Owing to the presence of various residual risks identifi ed for the refrigerated cabinet, ISA S.r.l. has fi tted cabinets in the JAMAICA series with hazard, warning and obligation signs devised in compliance with regulations relating to graphical symbols for use on systems.
  • Page 16: Installation

    KALEIDO VP 5. INSTALLATION 5.1 General Information This manual provides information on how to unpack and position as well as information on how to connect them to the power supply. 5.2 Storage and unpacking The refrigerated cabinet, with or without the packaging, should be carefully stored inside warehouses or in areas away from the elements and direct sunlight at a temperature between 0 and +40 °C.
  • Page 17: Operation

    KALEIDO VP 6. OPERATION 6.1 Preliminary operations / panel description Before the product is delivered to the customer, it is essential that a trained technical member of staff checks that the refrigerated cabinet is operating correctly in order to achieve maximum performance.
  • Page 18: Control Panel

    KALEIDO VP 6.3 Control panel In program, it pages through the codes of the parameters or increases the values. If it is pressed for 3 s it allows access to the section menu. Holding it pressed for 3 s start the manual defrost cycle.
  • Page 19 KALEIDO VP On (steady): Solenoid valve activated Blinking: Programming phase (blinking together with LED On (steady): Fan ON Blinking: Programming phase (blinking together with LED On (steady): Defrost activated Blinking: Dripping time in process On (steady): Keyboard in “ALL” mode...
  • Page 20 KALEIDO VP 428000346037...
  • Page 21: Routine Maintenance And Regular Checks

    KALEIDO VP 7. ROUTINE MAINTENANCE AND REGULAR CHECKS 7.1 Cleaning the refrigerated cabinet a) Remove the products from inside the tankand place them in a freezer immediately to ensure the product is preserved correctly. b) Cutting off the power by pulling the plug from the coupling point voltage.
  • Page 22: Cleaning The Condensing Unit

    KALEIDO VP 7.2 Cleaning the condensing unit ACCESSING THE CONDENSING UNIT - BACK a) Remove the screws from the protective grid. b) Remove the protective grid. c) Clean the condensing unit with a brush breathing. Clean the condensing unit with a soft brush.
  • Page 23: Special Maintenance

    KALEIDO VP 8. SPECIAL MAINTENANCE ADDITIONAL Special temperature conditions and high levels of humidity may whilst waiting for qualifi ed DEFROSTING generate frost on the evaporator, which reduces the perform- personnel to intervene ance of the refrigerated cabinet.Should these conditions persist over time, qualifi...
  • Page 24: Customer Support Centre

    KALEIDO VP 9. CUSTOMER SUPPORT CENTRE 9.1 Faults If the appliance is not working properly or stops working, before contacting the customer support centre, check the following: INCONVENIENCE PROBABLE CAUSES POSSIBLE SOLUTIONS The appliance is not working Interrupted protective fuse Find what triggered the switch and subsequently place the fuse back.
  • Page 25: List Of Alarms On The Electronic Controller (If Any)

    KALEIDO VP 9.2 List of alarms on the electronic controller (if any) ALARM DESCRIPTION / CAUSE STATUS OF SIGNAL Thermostat sensor broken Compressor control on parameters “Con” and “COF” Evaporator sensor broken Unchanged High temperature alarm Unchanged Low temperature alarm...
  • Page 26: Warranty Terms And Conditions

    KALEIDO VP 10. WARRANTY TERMS AND CONDITIONS The seller’s warranty on the equipment is valid for twelve months from the date of delivery. The warranty includes repairs or replacements of any faulty parts due to manufacturing processes or installation after written communication with the number of the model and date of installation.
  • Page 27: Annexes

    KALEIDO VP 11. ANNEXES Annex 1 - ..Electrical diagram - mod. condensing unit included Annex 2 - ... Electrical diagram - mod. remote condensing unit Annex 3 - .
  • Page 28 KALEIDO VP Annex 1 Electrical diagram (cod. 412100282000) (condensing unit included) 428000346037...
  • Page 29 KALEIDO VP Annex 2 Electrical diagram (cod. 412100283000) (remote condensing unit) 428000346037...
  • Page 30 KALEIDO VP Annex 3 DECLARATION OF CONFORMITY We: ISA Via del Lavoro, 5 - 06083 - Bastia Umbra (PG) certify on our own sole responsability that the product: KALEIDO VP Model: Serial Number: ....To which this declaration relates is in conformity with the following standards and other normatives documents: SAFETY OF MACHINERY General Electrical Safety Standards EN60335-1/Ed.2002+Amendments A11:2004,A1:2004,A12:2006,A2:2006,A13:2008 Special...

This manual is also suitable for:

120170220Ae45H117H135