The manual contains symbols to attract the reader's attention and highlight particularly important aspects. The table below illustrates the meaning of the various symbols used. Read the instruction manual Use of protective clothing Danger: Live electrical parts Requests for maintenance or operations must be carried out by qua- lifi...
1. MANUFACTURER ISA S.r.l. Via del Lavoro, 5 06083 - Bastia Umbra - Perugia - Italy Tel. +39 075 80171 Fax +39 075 8000900 www.isaitaly.com 2. WARRANTY TERMS AND CONDITIONS The seller guarantees the equipment for 12 (twelve) months from the date of delivery.
3. EQUIPMENT IDENTIFICATION • Find the label affi xed on the machine to read the technical data. • Check the machine model and the power supply voltage before you perform any operation. • If you uncover mismatches, contact the manufacturer or the company that supplied the machine immediately.
4. USE This appliance is exclusively intended to display and sell ice cream. The manufacturer is not liable for injury to persons or damage to property or the appliance itself caused by the displaying of products other than those described above. Never use electric devices inside this appliance.
Keep this manual in a safe place. It should be available for consultation near the equipment at all times. If lost or destroyed, you can request a copy of the manual from ISA S.r.l. by specifying the exact model, serial number and year of manufacture. The manual refl ects the manufacturing technology at the time of supply.
Page 8
INTRODUCTION ISA S.r.l. uses the best quality materials and their introduction on company premises, storage and use in production is continuously controlled to ensure the absence of damage, deterioration or malfunction.
6. SAFETY The appliance is equipped with safety devices: 6.1 SAFETY DEVICES INSTALLED Devices whose operation prevents the occurrence of risk situations in operating conditions (e.g. fuses, pressure switches, protections, magnet circuit breakers, etc.). 6.2 FIXED GUARDS Fixed protective devices consist of fi xed perimeter shields, which are used to prevent access to the internal parts of the machine.
6.6 FIRE Danger In the event of a fi re, immediately disconnect the master switch from the main power supply line. 6.7 EXPLOSIVE ATMOSPHERE The equipment must not be located in an area classifi ed as an explosion risk according to 1999/92/EC such as: Zone 0 An area in which there is a permanent, long-lasting or frequently explosive atmosphere made up of a...
6.13 REFRIGERANTS (where applicable) REFRIGERANT DESCRIPTION The refrigerant R290 is a gas that is compatible with the environment, but highly fl ammable. Pay close attention during transport, installation and that the destruction not to damage the refrigerant pipelines. IN THE EVENT OF DAMAGE: Keep fl...
7. DISPOSAL OF WASTE MATERIAL During normal operation, the appliance does not generate any environmental contamination. At the end of its life cycle, or if it is necessary to proceed to permanent decommissioning, we recommend following the procedures below: DISPOSAL (User) The symbol, applied to either the product or its packaging, indicates that the product should not be considered as normal domestic waste, but should be taken to a waste collection point for the recycling of electrical and electronic appliances.
8. INSTALLATION This manual supplies the information necessary for correct unpacking, procedures for positioning and connection to mains electricity. 8.1 STORAGE AND UNPACKING The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas away from the elements and direct sunlight, at a temperature between 00 and +40 °C. The appliance should only be moved by qualifi...
9. MAINTENANCE The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table below, calling the authorised Technical After-sales assistance when indicated. OPERATION FREQUENCY AUTHORISED PERSONNEL Cleaning the external surfaces Depending upon Use and Necessity User Cleaning the accessible internal parts Depending upon Use and Necessity...
Assistance If the control unit is set up especially for must R290 refrigerant, it must only be replaced with an original replacement from ISA. Replace the temperature probes only after checking which of the two is not operating effi ciently.
10.1 ALARMS LIST (if present) ALARM DESCRIPTION OUTPUTS AUTHORISED PERSONNEL Broken thermostat probe. The alarm starts a few seconds after the probe breaks down; it stops a Technical Compressor trip with few seconds after the probe starts working again properly. Assistance “COn”...
11. TECHNICAL SPECIFICATIONS 1189 x 1135 1519 x 1135 1684 x 1135 1849 x 1135 2179 x 1135 H117 mm x 1170 x 1170 x 1170 x 1170 x 1170 External dimensions (lxpxh) 1189 x 1135 1519 x 1135 1684 x 1135 1849 x 1135 2179 x 1135 H135 mm...
ICE CREAM CONTAINER DISPLAY KIT MODULARITY 11.1 INSTALLATION Attention It is fundamental to respect the distances indicated (mm) for correct installation of the appliance. aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa...
11.3 LEVELLING / POSITIONING Warning The standard appliance is equipped with height-adjustable feet. The appliance may be equipped (optional) with rotating wheels to make it easier to move. After it is positioned, the appliance must be stabilised on the fl oor by adjusting the feet until they do not rest on the wheels.
12. CONTROL PANEL Attention The electronic control boardis installed already programmed. Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. START-UP At the fi rst start-up and after any period of inactivity longer than 8 hours without power (with the socket unplugged), you must wait 1 hour and 30 minutes with the refrigerating cabinet powered (socket plugged), before starting the compressor.
13. CLEANING 13.1 INTERNAL a) Remove the product contained in the cabinet and put it immediately in cold storage in order to guarantee correct preservation. b) Shut off the appliance Wait at least 4 to 6 hours, until the ice on the evaporator has melted completely, before proceeding with cleaning operations.
14. ATTACHMENTS Code Page Declaration of Conformity Wiring diagram 412100583000 Wiring diagram 412100585000 GELATOSUPERSHOW USE AND MAINTENANCE MANUAL 428000533037...
Page 26
Attachment 1 DECLARATION OF CONFORMITY We: ISA S.r.l. Via del Lavoro, 5 - 06083 - Bastia Umbra (PG) declare under our own responsibility, that the product: GELATOSUPERSHOW Product: Serial number: XXXXXXXXXXXXXXXX To which this declaration refers, is in compliance with e following: MACHINERY SAFETY General electric safety Standard EN 60335-1/Ed.2002+Modifi...
Page 27
Attachment 2 - 412100583000 GELATOSUPERSHOW USE AND MAINTENANCE MANUAL 428000533037...