Axis Q1715 User Manual page 54

Hide thumbs Also See for Q1715:
Table of Contents

Advertisement

AXIS Q1715 Block Camera
The web interface
Shock detector: Turn on to generate an alarm if the device is hit by an object or if it is tampered with.
Sensitivity level: Move the slider to adjust the sensitivity level at which the device should generate an alarm. A low value
means that the device only generates an alarm if the hit is powerful. A high value means that the device generates an alarm
even with mild tampering.
Accessories
PTZ
Use PTZ drivers when you connect to external PTZ devices.
• Driver: Select the driver for your PTZ device. The driver is required for the connected device to function correctly.
• Device type: Select the type of device you're connecting to from the drop-down list. The device type is driver
dependent.
• Device id: Type the id, or address, of the connected PTZ device. You can find the address in the documentation of
the device.
For more information about PTZ drivers, see PTZ drivers on page 71.
I/O ports
Use digital input to connect external devices that can toggle between an open and closed circuit, for example, PIR sensors, door
or window contacts, and glass break detectors.
Use digital output to connect external devices such as relays and LEDs. You can activate connected devices through the VAPIX®
Application Programming Interface or the web interface.
Port
Name: Edit the text to rename the port.
Direction:
indicates that the port is an input port.
you can click the icons to change between input and output.
Normal state: Click
Current state: Shows the current state of the port. The input or output is activated when the current state is different from the
normal state. An input on the device has an open circuit when it's disconnected or when there is a voltage above 1 V DC.
Note
During restart, the output circuit is open. When the restart is complete, the circuit goes back to the normal position. If you
change any settings on this page, the output circuits go back to their normal positions regardless of any active triggers.
Supervised
: Turn on to make it possible to detect and trigger actions if someone tampers with the connection to digital
I/O devices. In addition to detecting if an input is open or closed, you can also detect if someone has tampered with it (that is, cut
or shorted). To supervise the connection requires additional hardware (end-of-line resistors) in the external I/O loop.
Edge-to-edge
Pairing
Pairing allows you to use a compatible Axis network speaker or microphone as if it's part of the camera. Once paired, the network
speaker acts as an audio out device where you can play audio clips and transmit sound through the camera. The network microphone
will take up sounds from the surrounding area and make it available as an audio input device, usable in media streams and recordings.
for open circuit, and
indicates that it's an output port. If the port is configurable,
for closed circuit.
54

Advertisement

Table of Contents
loading

Table of Contents