Fig. 2 :
DIP switch –
remove cover on
the door bolt
Tab. 1 :
Setting of the
unlock duration
via DIP switch S1
and S2
Tab. 2 :
Only in fail-un-
locked operation:
Switch off control
input if not used
EN
32

Electrical connection

DIP switch

The cover on the door bolt must be removed for switching the DIP switch (Fig. 1).
DIP switch S1 and S2
The unlock period is set via the DIP switches S1 and S2 (Tab. 1).
Seconds
DIP S1
0
ON
3
OFF
6
ON
9
OFF
DIP switch M
The DIP switch M is set for control input connection at the factory. For fail-un-
locked operation without control input, the DIP switch must be switched (Tab. 2).
Control input
not connected to the mains receiver
connected to the mains receiver
1.
DIP S2
ON
ON
OFF
OFF
Factory setting
DIP M
ON
OFF
Factory setting