Wiring and Connections

Overview

This chapter provides details, specifications, wiring diagrams, and other important information for all port and
connectors available on the MU-series controllers.

Serial Ports

The MU-series controllers each feature device control serial ports that support either RS-232 or RS-232, RS-422, and RS-
485 communication protocols. Each port supports the following specifications:
XON/XOFF (transmit on/transmit off)
CTS/RTS (clear to send/ready to send)
300-115,200 baud rate

RS-232 Ports

The RS-232 ports (ports 2-4 and 5-8 on the MU-3300; ports 2-4 on the MU-2300; port 2 on the MU-1300) are 5-pin 3.5
mm Phoenix connectors used for connecting A/V sources and displays. These ports support most standard RS-232
communication protocols for data transmission.
The following table lists the pinouts for the RS-232 ports.
RS-232 Port Pinout
Signal
GND
RXD
TXD
CTS
RS-232/422/485 Ports
The RS-232/422/485 ports (ports 1 and 5 on the MU-3300; port 1 on the MU-1300/2300) are 10-pin 3.5 mm Phoenix
connectors used for connecting A/V sources and displays
These ports support most standard RS-232, RS-422, and RS-485 communication protocols for data transmission.
RS-232/422/485 Pinout
Port Configuration
Signal
Function
RS-
232
GND
Signal Ground
X
RXD
Receive Data
X
TXD
Transmit Data
X
CTS
Clear to Send
X
RTS
Request to
X
Send
TX+
Transmit Data
TX-
Transmit Data
RX+
Receive Data
RX-
Receive Data
12VDC
Power
Function
Signal Ground
Receive Data
Transmit Data
Clear to Send
RS-
RS-
422
485
X
X
strap to RX+
X
X
strap to RX-
X
X
strap to TX+
X
X
strap to TX-