Page 1
Instructions - Parts List Membrane Air Drying System 309920D Model 234418, Series C Maximum Working Pressure 160 psi (1.1 MPa, 11 bar) Maximum Temperature 150° F (65° C) Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions...
Installation Installation 1. Before installing air line components, blow out the 3. Install air shut-off valve 288798 upstream from the pipe line to remove debris. Be sure air to the regula- air system to isolate it for service. tor is clean. Erratic operation or loss of regulation is 4.
Page 3
Shop Air Piping Layout Minimum Pipe Size Recommendations Compressor Main Air Line Size Capacity Length Size 1-1/2 - 2 HP 6 - 9 CFM 3/4” (19 mm) 3 - 5 HP 12 - 20 CFM Up to 200 ft. (61 m) 3/4”...
Operation Operation pressure drop across the element reaches 10-12 psi (69-83 kPa, 0.7-0.8 bar), the red indicator will be in full WARNING view, and the element should be replaced. Failure to replace the element when the pressure drop exceeds 10 Do not exceed the Maximum Incoming Air Pressure of psi (69 kPa, 0.7 bar) will affect your air quality and tool the equipment.
How Membrane Air Dryer Works How Membrane Air Dryer Works Wet air enters Water vapor purges Clean, dry air membrane module exits module Water vapor permeates through hollow membrane fibers Pressure Relief Procedure Air Filter with Auto Drain 234402, Series B To maintain maximum filtering efficiency and avoid excessive pressure drop, the filter must be kept clean.
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.