Time Update Interrupt Function; Time Update Interrupt Function Diagram - Epson RX-4803SA/LC Applications Manual

Real time clock module
Table of Contents

Advertisement

RX - 4803 SA / LC

8.4. Time Update Interrupt Function

The time update interrupt function generates interrupt events at one-second or one-minute intervals, according to
the timing of the internal clock.
When an interrupt event occurs, the UF bit value becomes "1" and the /INT pin goes to low level to indicate that
an event has occurred. (However, when a fixed-cycle timer interrupt event has been generated, low-level output
from the /INT pin occurs only when the value of the control register's UIE bit is "1". This /INT status is
automatically cleared (/INT status changes from low level to Hi-Z) 7.8 ms (fixed value) after the interrupt occurs.
/INT operation
example
UIE = " 1 "

8.4.1. Time update interrupt function diagram

UIE bit
/INT output
UF bit
Events
Operation in RTC
i '
i
Write operation
(1) A time update interrupt event occurs when the internal clock's value matches either the second update time
or the minute update time. The USEL bit's specification determines whether it is the second update time or
the minute update time that must be matched.
(2) When a time update interrupt event occurs, the UF bit value becomes "1".
(3) When the UF bit value is "1" its value is retained until it is cleared to zero.
(4) When a time update interrupt occurs, /INT pin output is low if UIE = "1".
∗ If UIE = "0" when a timer update interrupt occurs, the /INT pin status remains Hi-Z.
(5) Each time an event occurs, /INT pin output is low only up to the tRTN time (which is fixed as 7.1825 ms for
time update interrupts) after which it is automatically cleared to Hi-Z.
∗ /INT pin output goes low again when the next interrupt event occurs.
(6) When /INT = low, the /INT pin status changes from low to Hi-Z as soon as the UF bit value changes from "1"
to "0".
(7) When /INT = low, the /INT pin status changes from low to Hi-Z as soon as the UIE bit value changes from
"1" to "0".
7.8ms
period
" 1 "
(4)
(5)
tRTN
(3)
(2)
period
period
(1)
Page - 19
UIE = " 1 " → " 0 "
(7)
tRTN
tRTN
(6)
∗ /INT status change
when UF bit is cleared
to zero.
period
period
" 1 "
" 0 "
Hi - z
" L "
tRTN
" 1 "
" 0 "
ETM33E-04

Advertisement

Table of Contents
loading