SENSOR-SPECIFIC MESSAGES
Periodic Reports
The weather station bridge sends all data on a periodic basis. This period is defined in byte 1 of the downlink
message. The period is expressed in 1 hour increments when the most significant bit is 0, and in 1 minute
increments when the most significant bit is 1 as shown in the following table.
Period Bye from Downlink Configuration Message
Bit 7
0
1
For example, to receive a report every 4 hours, byte 1 would be set to 0x04. To receive a periodic report every 15
minutes, byte 1 would be set to 0x8f.
24
Bits 6:0
Period defined in hours (1-127 hours)
Period defined in minutes (1-127 minutes)
®
Radio Bridge LoRaWAN
Wireless Sensor Air Temperature Humidity Sensor User Guide