Periodic Reports

The temperature sensor can also send periodic updates, and this is defined in byte 1 of both modes. A setting of 0
will disable periodic reporting. The period is defined in 1 hour increments when the most significant bit is 0, and it
is defined in 1 minute increments when the most significant bit is 1 as shown in the following table.
Period Bye (byte 1) from Downlink Configuration Message
Bit 7
0
1
For example, to receive a report every 4 hours, byte 1 would be set to 0x04. To receive a periodic report every 15
minutes, byte 1 would be set to 0x8f.
Note that prior to firmware version 1.3, only hourly reporting is available. The firmware version can be found in
the reset message and is logged on the console.
Periodic reporting is not recommended as regular practice as its use increases data service fees and significantly
reduces battery life. Wherever possible, use thresholds or report-on-change only.
®
Radio Bridge LoRaWAN
Bits 6:0
Period defined in hours (1-127 hours)
Period defined in minutes (1-127 minutes)