Device Info Request

The Device Info Request command is a downlink to inform the gateway to report its downlink configuration
information.
Bit
Description
0x00
Downlink configuration type
to request.
0-254: Request device
info for specific downlink
type to report.
255: Request device info
for all downlink
configurations.

Link Quality Configuration (0xEE)

The Link Quality configuration command configures the number of failed confirmed message attempts before re-
entering the LoRaWAN join state.
Byte
0x00
®
Radio Bridge LoRaWAN
Description
Number of failed confirmed message transmits before the device re-enters a LoRaWAN
join state. The default value is 12.
When the device transmits a confirmed message and exhausts uplink retries without
receiving an acknowledgment, the device increments an internal failed counter by 1.
This counter not increment if the message being transmitted is not a confirmed
message.
If this counter does not exceed the threshold specified in this byte, the device
attempts a retransmit.
The default value is 12.