Page 1
Data Acquisition System DAQ-9600 USER MANUAL ISO-9001 CERTIFIED MANUFACTURER Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com 127 rue de Buzenval BP 26 - 92380 Garches...
Page 2
This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the right to change specifications, equipment, and maintenance procedures at any time without notice.
Table of Contents Table of Contents SAFETY INSTRUCTIONS ............ 5 Safety Symbols ................5 Safety Guidelines ................ 6 GETTING STARTED ............10 Characteristics ................11 Front Panel Overview ..............13 Rear Panel Overview ..............17 Status Bar ................... 19 Set Up ..................22 MODULE OVERVIEW ............
Page 4
DAQ-9600 Series User Manual DIGITAL I/O ..............134 Digital I/O Overview ..............135 Application: Alarm Output ............137 Application: External Trigger ............139 SYSTEM & FIRMWARE ........... 140 View System Info ............... 141 Firmware Update ............... 142 MENU SETTING ............. 144 Configure System ...............
DAQ-9600 in the best possible condition. Safety Symbols These safety symbols may appear in this manual or on the DAQ-9600. Warning: Identifies conditions or practices that could result in injury or loss of life.
DAQ-9600 Series User Manual Safety Guidelines Make sure that the measurement voltage input level General Guideline does not exceed DC600V/AC400V. CAUTION Do not place any heavy object on the instrument. Avoid severe impact or rough handling that can lead to ...
Page 7
SAFETY INSTRUCTIONS The transient overvoltage may be present on the measuring circuits. Refer to the table below for the transient overvotlage on general mains circuits. Rated impulse withstand voltage Voltage line to neutral derived from nominal Overvoltage Category voltages AC or DC up to and including 1500 1500...
Page 8
Altitude: <2000m (Note) EN 61010-1 specifies the pollution degrees and their requirements as follows. The DAQ-9600 falls under degree 2. Pollution refers to “addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Page 9
SAFETY INSTRUCTIONS Do not dispose this instrument as unsorted municipal Disposal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Please make sure discarded electrical waste is properly recycled to reduce environmental impact. Tél.
Page 10
DAQ-9600. Please note the information in this manual was correct at the time of printing. However as GW Instek continues to improve its products, changes can occur at any time without notice. Please see the GW Instek website for the latest information and content.
GETTING STARTED Characteristics The DAQ-9600 is a portable, dual-display digital multimeter suitable for a wide range of applications, such as production testing, research, and field verification. The highest DCV accuracy: 35ppm Performance The highest current:2A The highest voltage: 600VDC,400VAC ...
DAQ-9600 Series User Manual Accessories Standard Part number Description Accessories 82xx-xxxxxxxx Safety Instruction Sheet Optional Part number Description Accessories GTL-246 USB Cable, USB 2.0, A-B type, 1200mm GTL-258 Mini GPIB Cable, approx. 1.9m GRA-422 Rack Mount Kit (19” 2U) GRA-436 Rack Mount Kit (19”, 2U)
GETTING STARTED Front Panel Overview Home Data Acquisition System Monitor Scan : Long Push Enter Channel Interval Edit Alarm View Module Math Average Auto ON / STBY Menu Lock Local Item Description USB Host Port Power Switch Main Display Function keys (F1 through F6, functions vary per modes) Operation menus keys for measurement Configuration menus keys for parameters (also the numerical keypad functions)
Page 14
DAQ-9600 Series User Manual Connects with USB flash drive for data log storage and screenshot hardcopy. USB Host Port Power On/Standby switch with LED lights Power Switch (green: power on, red: standby). For the power up sequence, see page 23.
Page 15
GETTING STARTED The 9 configuration-related menus keys are well described Configuration below. menus keys Press to enter the Channel setting menu for Channel Key each channel. Refer to the page 52 for details of channel configurations. When inputting parameters values, it acts a direct number key – Press to enter the Interval setting menu for all Interval Key channels.
Page 16
– 3. Press to enter the general Menu setting page for Menu Key DAQ-9600 unit. Refer to the page 145 for details of menu configurations. When inputting parameters values, it acts a direct number key – 0. Press and hold for 1 second to lock all keys on Lock Key panel.
GETTING STARTED Rear Panel Overview LINE RATING Mini GPIB 50/60Hz 50VA MAX. FUSE LINE 100V 250V 120V T0.125A 220V 240V Disconnect power cord and test leads before replacing fuse. For continued fire protection , use specified line fuse. Digital I/O WARNING To avoid shock , remove inputs before opening.
Page 18
DAQ-9600 Series User Manual DAQ-9600 provides up to 3 slots Slots for Modules for plug-in modules installation. Installation Refer to page 25 for details of Modules. It accepts a mini GPIB cable for Mini GPIB Port remote control. For GPIB details, see page 186.
GETTING STARTED Status Bar Identify each icon within the top status bar. Background Status Bar 0 A B C 1 2 3 4 5 Display Item Description Local/Remote control icon USB-CDC/USB-TMC/LAN/GPIB interface icon Error icon for commands from remote control Locked key icon Alarm triggered icon Monitor mode underway icon...
Page 20
DAQ-9600 Series User Manual It indicates the unit is under local Local Control control mode. It indicates the unit is under remote Remote Control control. Refer to page 179 for details. It indicates USB - CDC interface is USB - CDC activated.
Page 21
GETTING STARTED It indicates the Scan mode is ongoing. Scan mode Press and hold the Scan key for 1 second to exit and the icon will disappear. Refer to page 48 for details. It indicates the internal memory for scan Internal memory data has reached 100,000 readings.
DAQ-9600 Series User Manual Set Up Horizontal/Tilt/Vertical Applications Data Acquisition System Home Monitor Scan : Long Push Enter Channel Interval Edit Alarm View Module Average Math Auto ON / STBY Menu Lock Local Pull out the handle sideways and rotate it clockwise for the applications below.
GETTING STARTED Power Up 1. Ensure the correct line voltage is Steps clearly shown on the fuse socket (240V in the right figure for example). If not, see page 336 to set the proper line voltage and fuse. 2. Connect the power cord to the AC Voltage input.
Page 24
DAQ-9600 Series User Manual ODULE OVERVIEW Modules List ................25 Module Installation..............26 Module Uninstallation ............... 27 Modules Introduction ..............27 DAQ-900 20-Channel Solid-State Multiplexer ....28 DAQ-901 20-Channel Armature Multiplexer ...... 29 DAQ-903 40-Channel Single-Ended Multiplexer ......30 DAQ-904 4 x 8 Two-Wire Matrix Switch ........31 DAQ-909 8-Channel High Voltage Multiplexer ....
MODULE OVERVIEW Modules List The DAQ-9600 is available for a series of plug-in modules to Background provide user with measurements, switching as well as control capabilities. Each module owns specific microprocessor, which efficiently shares loading from the processor of mainframe and thus lessens, in order to faster throughput, backplane communications.
DAQ-9600 Series User Manual Module Installation Follow the steps below for how to connect wire to a module Background and install it to a slot from the rear panel of DAQ-9600 unit. Use a Phillips-head Steps screwdriver to loose the screw from the...
DAQ-9600 unit. To install/uninstall the modules from the slots of rear panel in the midst of power on will reboot the DAQ-9600 unit. Note Modules Introduction This subchapter introduces each plug-in module with block Background diagram and schematics available for DAQ-9600 unit.
DAQ-9600 Series User Manual DAQ-900 20-Channel Solid-State Multiplexer Partitioned into 2 banks and each bank consists of 10 two- wire Background channels, this module has up to 20 channels, which switch both Hi and Lo inputs, and it offers fully isolated inputs to an external device or to the internal DMM.
MODULE OVERVIEW DAQ-901 20-Channel Armature Multiplexer Partitioned into 2 banks and each bank consists of 10 two- wire Background channels, this module has two additional fused channels to make direct and calibrated AC or DC current measurement with internal DMM. The 22 channels in total, which switch both Hi and Lo inputs, offer fully isolated inputs to an external device or to the internal DMM.
DAQ-9600 Series User Manual DAQ-903 40-Channel Single-Ended Multiplexer This module is partitioned into 2 banks and each bank consists Background of 20 channels. The all 40 channels, with a common Lo for the module, switch Hi only. This module is suitable for applications of high-density switching which are in demand of, with a common Lo, single-wire inputs.
MODULE OVERVIEW DAQ-904 4 x 8 Two-Wire Matrix Switch Organized in a 8-column by 4-row configuration, this module Background consists of 32 two-wire crosspoints. By connecting columns and rows between multiple modules, it is available to build larger matrices with up to 96 crosspoints within a mainframe. Also, user can utilize this module to connect to multiple instruments to multiple points or to any hybrid of outputs and inputs on DUT simultaneously.
DAQ-9600 Series User Manual DAQ-909 8-Channel High Voltage Multiplexer Partitioned into 2 banks and each bank consists of 4 two- wire Background channels, this module has two additional fused channels to make direct and calibrated AC or DC current measurement with internal DMM.
DAQ-9600 Series User Manual Home Mode Press and hold the Home key on the front panel Background for 1 second to enter the Home menu in which several basic settings are displayed. Refer to the diagram below for details. Home Menu...
Page 35
OPERATION MENUS Home Function Keys Selection Alarm Latch: F1 (AlarmOut) Mode key to set up The triggered alarm output is remained unti user alarm mode clear the alarm manually. relevant settings Track: The triggered alarm output is automatically cleared when a measured reading is within limits.
Page 36
DUTs provided by DAQ-9600 simultaneously. In this case, turn Off the DMM function and thus DAQ-9600 simply acts as a multiple channles switch hub and reroutes signals received from connected DUTs to the external DMM for measurment.
Page 37
OPERATION MENUS If user configures channel(s) for strain measurement, Strain F5 (Strain) key Offset is available for calculating strain measurement. to set up Offset value for Strain Select Press to launch strain channel list where available measurement channel(s) set in strain measure are shown for select.
DAQ-9600 Series User Manual Monitor Mode Press the Monitor key on the front panel to launch Background the monitor function to see real-time measured reading on a select channel. When the Scan mode is activated with Monitor mode simultaneously, the measured reading on a select channel is updated only when the select channel being scanned by a sweep within a scan course.
OPERATION MENUS Display - Number Function Keys in Display – Number Number The screen shows the Number mode for reading F1 (Display) key display. And the maximum digits for number to enter Number display depend on the Digit configuration. display ...
DAQ-9600 Series User Manual Display – Bar Meter Function Keys in Display – Bar Meter The screen shows Bar Meter display in lower F1 (Display) key Meter section along with Number display in top for to enter Bar reading display. And the maximum digits for Meter display Number display depend on the Digit configuration.
OPERATION MENUS Center for Method When Center is selected, it is available to further determine the exact Center value and the Span Scale for the meter bar display. Center: +0.0 Span: +4.000 (+2.000 - -2.000) Scale – Manual - Center Display –...
Page 42
DAQ-9600 Series User Manual L & H for Manual After L and H are set up individually, the vertical upper and lower ranges are corresponding to the set values accordingly. High:+0.20000 Low:-0.20000 VScale – Manual – L & H Auto(Once) for Manual...
Page 43
OPERATION MENUS Stop&View - Range: Press Stop&View key to stop measurement and view detailed info on the trend chart. Press Range key followed by scrolling Knob key rightward or leftward to move cursors on different sections. Green The total counts of measurements Sect.
Page 44
DAQ-9600 Series User Manual Stop&View – Cursor 1 & Cursor 2: Press Stop&View key to stop measurement and view the lowest and highest values of each count on the trend chart. Scroll Knob key rightward or leftward to move cursors on different sections.
OPERATION MENUS Display – Histogram Function Keys in Display – Histogram Histogr The screen shows the Histogram display in lower F1 (Display) key along with Number display in top for reading to enter display. And the maximum digits for Number Histogram display depend on the Digit configuration.
Page 46
DAQ-9600 Series User Manual Hscale - Auto: The horizontal scale of histogram is symmetric with the set speed of measurement. For example, setting 50/s results in a faster horizontal histogram speed, whilst 1/s leads to a slower horizontal histogram speed.
Page 47
OPERATION MENUS Stop&View - Class: Press Stop&View key to stop measurement and view detailed info on the histogram. Scroll the Knob key rightward or leftward to move cursors on different bins. Green It indicates the selected bin number. Sect. Scroll the knob key right or left to change bin number for checking.
Also, the Computer channels (401-420), whose computed formula are configured previously, will be scanned by DAQ-9600 in a scan course as well. Refer to page 88 for details of Computer channels. For those channels whose measurement functions are Not configured previously, the Scan mode will skip them from a scan course.
Page 49
OPERATION MENUS START The status becomes START after user Scan /STOP presses Scan key. And it turns STOP after Display a scan course is completed or after user presses and holds Scan key for 1 second. Next It indicates the interval actions between Sweep each sweep.
DAQ-9600 Series User Manual Scan Mode with Monitor Mode simultaneously It is available for user to activate both Scan mode and Monitor Description mode at the same time. When Scan mode is activated with Monitor mode simultaneously, the measured reading on a select channel is updated once only when the select channel is being scanned by a sweep within a scan course.
DAQ-9600 Series User Manual Channel Menu Press the Channel key on the front panel to enter Background the Channel menu in which various measurements Channel can be selected for each channel from slots modules. Refer to the diagram below for details.
Page 53
CONFIGURATION MENUS Channel Function Keys Selection Press the F1 key to select a channel. Use either numerical F1 (Channel) key keypad or rotate knob key to confirm selection. Also, it is to select a available directly rotate knob key from Channel display to channel navigate channels.
DAQ-9600 Series User Manual DCV/ACV Measurement The DC and AC voltage measurements configurations. Description F3 (Measure) key to select ACV or Voltage source and module terminals connection Press the key to enter Range menu and select a target F4 (Range) key to range for ACV and DCV measurements individually.
Page 55
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 56
DAQ-9600 Series User Manual Voltage Conversion Table This table shows the relationship between AC and DC Background reading in various waveforms. Waveform Peak to Peak (True RMS) 2.828 1.000 0.000 Sine PK-PK 1.414 0.435 0.900 Rectified Sine (full wave) PK-PK 2.000...
Page 57
CONFIGURATION MENUS Crest Factor Table Crest factor is the ratio of the peak signal amplitude to the Background RMS value of the signal. It determines the accuracy of AC measurement. If the crest factor is less than 3.0, voltage measurement will not result in error due to dynamic range limitations at full scale.
DAQ-9600 Series User Manual Temperature Measurement The temperature measurements configurations. Description Generally, it requires a temperature transducer with the supported probes Thermocouple, Thermistor and Resistance Temperature Detector (RTD). Thermocouple -200°C ~ +1820°C (vary by sensor types) Temperature -200°C ~ +630°C...
Page 59
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 60
In order to authenticate the proper connection of Open Check (F3) thermocouples for measurements, turn on the Open key to set open Check feature. When activated, DAQ-9600 executes a circuit resistance measurement alongside each temperature authentication assessment to detect any open circuits. Should one be identified, the outcome will display as +Overload.
Page 61
CONFIGURATION MENUS Reference Junction Temperature (SIM Temperature) When a thermocouple is connected to the DAQ-9600, the Background temperature difference between the thermocouple lead (Thermocouple and the DAQ-9600 input terminal should be taken into only) account and be cancelled out; otherwise an erroneous temperature might be added.
Page 62
DAQ-9600 Series User Manual Thermistor 2W/4W Setting TEMP F3 (Measure) key to select TEMP Them2W F4 (Probe) key to select Them2W or Them4W Them4W Therm2W Therm4W Thermistor and module terminals connection Type Range Resolution Parameter -80~150°C 0.001°C Press the key to enter Speed menu and select a target F5 (Speed) key to speed temperature measurements.
Page 63
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 64
DAQ-9600 Series User Manual Press the key to enter the next page (More 3/3) of more F6 (More 2/3) key functions configurations for measurement. to enter next function keys page Function Keys in More 3/3 page Selects the low-power resistance measurement, which...
Page 65
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 66
DAQ-9600 Series User Manual Equation -200°C to 0°C range -0°C to 630°C range Enable Use as Ref to make selected channel be used as Use as Ref (F5) the reference channel for subsequent thermocouple key to enable measurements that specify an external reference source.
The deformation per unit length is the so-called strain. Strain may be either compressive (-) or tensile (+). DAQ-9600 supports two types of strain measurements which are Bridge and Direct resistive methods. After configuring strain measurement function for...
Page 68
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 69
CONFIGURATION MENUS Strain bridge conversions require the voltage of the Excitation (F2) key external bridge excitation, for which user can designate a multiplexer channel to measure the excitation voltage or can specify a known fixed voltage value. Fixed (Fix) - The fixed value specified by the excitation voltage will be used for the strain conversion.
Page 70
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 71
CONFIGURATION MENUS Press the key to enter the next page (More 3/3) of more F6 (More 2/3) key functions configurations for measurement. to enter next function keys page Function Keys in More 3/3 page User specifies a Poisson ratio, which is defined as the PoisRatio(F1) key negative ratio of the strain in the transverse direction to the strain in the longitudinal direction, of the strain gage.
Page 72
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 73
CONFIGURATION MENUS Press the key to enter the Config menu followed by Config (F3) key to selecting Full. specify Full Press the key to enter the Type menu followed by Type (F4) key to selecting BendPois for type, which is a combination ratio select BendPois of Bening and Poisson.
Page 74
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 75
CONFIGURATION MENUS Press the key to enter the Sense menu followed by Sense (F2) key to selecting Bridge for sense. select Bridge Press the key to enter the Config menu followed by Config (F3) key to selecting Quarter. specify Quarter Gage factor indicates the ratio of fractional change in GageFactor (F5) resistance to, along the axis of the gage, the fractional...
Page 76
DAQ-9600 Series User Manual 2W & 4W Direct Setting STRAIN F3 (Measure) key to select STRAIN 2W Direct 4W Direct Direct source and module terminals connection Under the either 2W or 4W Direct setting, the Range is F4 (Range) key is fixed in Fix 1 by default.
Page 77
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
DAQ-9600 Series User Manual 2-Wire & 4-Wire Resistance Measurement The resistance measurements configurations. Generally, Description the 2-Wire resistance indicates using the standard Input HI-LO terminals and it is recommended for measuring resistances larger than 1kΩ. And 4-Wire resistance indicates compensating the test lead effect using the 4W compensation terminals, in addition to the standard Input HI-LO terminals.
Page 79
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
DAQ-9600 Series User Manual Frequency/Period Measurement The frequency/period measurements configurations. Description FREQ F3 (Measure) key to select either Frequency or Period PERIOD Input source and module terminals connection Press the key to enter Range menu and select a target F4 (Range) key to range for Frequency/Period measurements individually.
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
DAQ-9600 Series User Manual Capacitance Measurement The capacitance measurement configurations. Description F3 (Measure) key to select capacitance Capacitance source and module terminals connection Press the key to enter Range menu and select a target F4 (Range) key to range for capacitance measurement. The Auto indicates a...
CONFIGURATION MENUS DCI/ACI Measurement The DCI and ACI current measurements configurations. Description Both DC and AC current measurements are available on Note the channels 21 and 22 of DAQ901module only. F3 (Measure) key to select either ACI or DCI Current sources and module terminals connection...
Page 84
DAQ-9600 internally measures the offset following each measurement. It then subtracts that measurement from the preceding reading. This prevents offset voltages present on the DAQ-9600 input circuitry from affecting measurement accuracy. With autozero Off, DAQ-9600 measures offset once and subtracts the offset from all subsequent measurements.
Page 85
CONFIGURATION MENUS Scan 2-Wire & 4-Wire Measurement The 2-wire and 4-wire connections are available for Description diversified measurements connected with external DMM unit when internal DMM function is disabled. In accord with varied measurements for different DUTs, select and physically wire the applicable 2W or 4W connections. Only when DMM function is disactivated can both Note “Scan 2W”...
DAQ-9600 Series User Manual Switch Mode for Channels The Switch mode from multiplexer modules empowers user Background to open and close channels individually. We will instroduc how to turn on and configure channels to the Switch mode in details. Switch mode is available on the multiplexer DAQ900, Note DAQ901 and DAQ903 modules only.
Page 87
CONFIGURATION MENUS 4. Press the Channel key from the front panel. It is seen that the Measure is OFF for the channel 101 and the Switch key and JoinBank key are available for On or Off by user. Switch: To enable or disable switch for each channel.
DAQ-9600 Series User Manual Computer Channels Computer channels (401 – 420) can execute various Background mathematical operations from readings of measurement channels or other computer channels. To execute mathematical operations in computer Note channels, it is required to set up measurement channels beforehand.
CONFIGURATION MENUS Basic Math An example of mathematical operation A + B on the Description channel 401 will be illustrated below. 1. From the example below in the Channel menu, the Steps Computer (F3) key is turned On and the Formula (F4) key is configured A + B.
DAQ-9600 Series User Manual Statistics An example of mathematical operation AVF(List) on the Description channel 401 will be illustrated below. 1. From the example below in the Channel menu, the Steps Computer (F3) key is turned On and the Formula (F4) key is configured AVG(List).
CONFIGURATION MENUS Polynomial 5TH An example of mathematical operation on the Description 5TH(A) channel 401 will be illustrated below. 1. From the example below in the Channel menu, the Steps Computer (F3) key is turned On and the Formula (F4) key is configured 5TH(A).
DAQ-9600 Series User Manual Interval Menu Press the Interval key on the front panel to enter the Background Interval menu to configure the method to start each sweep and a total number of sweeps for a scan course. The screen layout of Interval menu is almost identical to that of Home screen and is only different in the function keys.
Page 93
CONFIGURATION MENUS Manual It indicates a manual trigger. When selecting this method, user needs to press the Scan key on the front panel to start each sweep for a scan course. During a scan course, each sweep only starts when user presses the Scan key.
Page 94
(#1 - #4) is used to report on the select Alarm) key channel. specify alarm It specifies a total number of times of sweeps that DAQ-9600 F3 (Sweeps) will run through a scan course. key specify number...
CONFIGURATION MENUS Edit Menu Press the Edit key on the front panel to enter the Background Edit menu in which user is able to copy measurement functions, alarm settings and so on from channels to channels with ease. Edit Menu Diagram Source Dest.
DAQ-9600 Series User Manual Copy Channels Channel(s) copying can be performed in various ways: Description one-to-one, one-to-many and many-to-many. In this chapter an example of many-to-many channels copying is illustrated. 1. Press the Edit key on the front panel to enter the Edit menu...
Page 97
CONFIGURATION MENUS 4. Use knob key to navigate channels followed by pressing Select or SelectAll to select destination channels. Press Cancel or ClearAll to deselect channels. Press OK to confirm selection. Press Exit to leave the page without saving the selection. Those selected as source channels previously will not displayed here within the Dest.
DAQ-9600 Series User Manual Alarm Menu Press the Alarm key on the front panel to enter the Background Alarm menu to configure the conditions of triggered alarm for select channels. The screen layout of Alarm menu is almost identical to that of Channel menu and is only different in the function keys.
CONFIGURATION MENUS Alarm Configuration This section demostrates how to configure alarm conditions Description for each selected channels. 1. Press the Alarm key on the front panel to enter the Alarm menu Steps and use the knob key to navigate channels to select a target one (channel 201 for example below).
Page 100
DAQ-9600 Series User Manual 5. Press the Scan key on the front panel to initiate a scan course. When the set alarm occurs for select channel during a scan course, the alarm status will be shown clearly as the following example.
CONFIGURATION MENUS View Menu Press the View key on the front panel to enter the Background View menu where several relevant info after scanned measurement including Data, Alarm, Error and RelayCycle are displayed for user to have better understanding of measured info by a scan course. Data View This section introduces view menu for measured scan Data, Background...
Page 102
DAQ-9600 Series User Manual 3. The list mode displays Date, Time, Channel, Channel Label (naming by user) and reading of each measured data from a scan course. Statistics Display 1. Press the View (F1) key followed by pressing the Data (F1) Steps key.
Page 103
CONFIGURATION MENUS 3. The statistics mode displays Channel, Mininum, Maximum, Pk-Pk (Peak-to-Peak), Average and STDEV (Standard Deviation) of readings data from a scan course. 4. Press the Mode (F3) key to toggle between STAT (Statistics) and TIM (Time Stamp) displays. The TIM mode displays the Date &...
Page 104
DAQ-9600 Series User Manual 2. When the “CH” is selected for ViewMode (F3) key, scroll the knob key to navigate through channels. 3. When the “GRH” is selected for ViewMode (F3) key, scroll the knob key to navigate through scanned counts. If pressing knob key, the maximum counts moving by scrolling knob key per time will be changed.
Page 105
CONFIGURATION MENUS VScale - Manual: It allows the vertical scale of trend chart to be customized in the following 2 ways. L & H for Manual After L and H are set up individually, the vertical upper and lower ranges are corresponding to the set values accordingly.
Page 106
DAQ-9600 Series User Manual KnobMode - Range: (KnobMode) It allows user to view detailed info on the trend chart. key to view in Press Range key followed by scrolling knob key rightward details or leftward to move cursors on different sections.
Page 107
CONFIGURATION MENUS KnobMode – Cursor 1 & Cursor 2: It allows user to view the lowest and highest readings of each count on the trend chart. Press the Cursor1 (F2) or Cursor2 (F3) key followed by scrolling knob key rightward or leftward to move cursors on different sections.
Page 108
DAQ-9600 Series User Manual Histogram Display 1. Press the View (F1) key followed by pressing the Data (F1) Steps key. And then press the Display (F2) key followed by selecting the Histogram (F4) key to enter the page of scanned data in Histogram display.
CONFIGURATION MENUS Alarm View This section introduces view menu for Alarms. Only when Description alarm setting is configured beforehand for select channel, the alarm list will display details of channel, limit, reading and time stamp of the latest 40 alarms. Refer to page 98 for details of how to configure alarms.
DAQ-9600 Series User Manual Error View This section introduces view menu for Errors. The Error list Description displays Code and String of the latest 20 errors. After user reads the Error list here, the ERR icon on the top status bar will be erased and the whole Error list will be cleared.
CONFIGURATION MENUS Relay Cycle View This section introduces view menu for Relay Cycle of each Description channel from the installed module. It empowers user to track if any relay failures or to figure out requirements of maintenance. 1. Press the View (F1) key followed by pressing the RelayCycle Steps (F4) key.
DAQ-9600 Series User Manual Module Menu Press the Module key on the front panel to enter the Background Module menu where user can view circuit diagrams of installed modules, check both scan and switch status of channels from installed modules and proceed to firmware update for installed modules.
Page 113
Yes (F1) to carry on the update. Connect an USB disk containing compatible firmware file to Note the USB host port on front panel of DAQ-9600 before proceeding to FW Update for installed module. Tél. 01 47 95 99 45 e-mail : tem@es-france.com...
DAQ-9600 Series User Manual Math Menu Press the Math key on the front panel to enter the Background Math menu. Math measurement runs 5 types of mathematical equations, dB, dBm, MX+B, 1/X and Percent, based on the measurement results of each channel.
Page 115
CONFIGURATION MENUS Press the key to show the MathDisp menu for 4 different F2 (MathDisp) displays. See the following descriptions for details. key to select display modes Only when Alarm configuration is enabled can the “Alarm” and “ALR+STAT” of Math Display are available to activate. Note Description The STAT page in MathDisp allows user to Show STAT...
Page 116
DAQ-9600 Series User Manual Description The Alarm page in MathDisp allows user to Show Alarm track if measured data exceeds the set High Result and Low limits, individually. Values Low Limit Indicates the set low limit of channel High Limit...
CONFIGURATION MENUS dB Measurement dBm – dBmref Math Equation F1 (Function) key to select dB equation Press the key to enter the menu to change the reference F3 (REF Ω) key to resistance, which indicates reference resistance simulating an select reference output load.
Page 118
DAQ-9600 Series User Manual Description The STAT page in MathDisp allows user to Show STAT make statistical calculations for measurements Result including Minimum, Maximum, Average Peak-Peak, Standard Deviation and Count. Values +03.01737 dB Indicates the latest dB value Minimum Indicates the minimum value...
Page 119
CONFIGURATION MENUS Description The Alarm page in MathDisp allows user to Show Alarm track if measured data exceeds the set High Result and Low limits, individually. Values Low Limit Indicates the set low limit of channel High Limit Indicates the set high limit of channel Low Fail Inidcates the numbers of low limit exceeding...
DAQ-9600 Series User Manual MX+B Measurement Multiplies the reading (X) by the factor (M) and Math Equation adds/subtracts offset (B). MX+B F1 (Function) key to select MX+B equation Press the key to enter the menu to configure a M (Gain) F3 (M Value) key value for MX+B equation.
Page 121
CONFIGURATION MENUS Maximum Indicates the maximum value Average Indicates the average value Peak-Peak Indicates the peak to peak value STDEV Indicates the standard deviation value Count Indicates the latest counts of MX+B Description The Math page in MathDisp allows user to view Show Math mathematical calculations for several parameters.
Page 122
DAQ-9600 Series User Manual Description The ALR+STAT page in MathDisp allows Show user to view information from both STAT and ALR+STAT Alarm pages simultaneously. Result Values Left Sec. The numbers of High and Low limits exceeding are shown individually. Right Sec.
CONFIGURATION MENUS Press the key to show the Decimal Point menu to configure F5 (Decimal PT) either Auto or Range mode for Monitor display. Auto means key to configure that the unit of measured reading fluctuates with the actual measured condition, whilst Range indicates that the unit of measured reading is fixed in accord with the set range setting.
Page 124
DAQ-9600 Series User Manual Description The STAT page in MathDisp allows user to Show STAT make statistical calculations for measurements Result including Minimum, Maximum, Average Peak-Peak, Standard Deviation and Count. Values +0.141745 k Indicates the 1/X calculation Minimum Indicates the minimum value...
Page 125
CONFIGURATION MENUS Description The Alarm page in MathDisp allows user to Show Alarm track if measured data exceeds the set High Result and Low limits, individually. Values Low Limit Indicates the set low limit of channel High Limit Indicates the set high limit of channel Low Fail Inidcates the numbers of low limit exceeding...
DAQ-9600 Series User Manual Percent Measurement Math (ReadingX – Reference) x 100% Equation Reference Percent F1 (Function) key to select Percent equation Press the key to enter the menu to configure a Reference F3 (REF %) key value for Percent equation.
Page 127
CONFIGURATION MENUS Count Indicates the latest counts of Percent Description The Math page in MathDisp allows user to view Show Math mathematical calculations for several parameters. Result Values -0.199167 k Indicates the Percent calculation Measure Indicates the originally measured Voltage value REF % Indicates the defined reference % value...
Page 128
DAQ-9600 Series User Manual Description The ALR+STAT page in MathDisp allows Show user to view information from both STAT and ALR+STAT Alarm pages simultaneously. Result Values Left Sec. The numbers of High and Low limits exceeding are shown individually. Right Sec.
CONFIGURATION MENUS Average Menu Press the Average key on the front panel to enter Background the Average menu. The digital average function averages a specified number of input signal samples to generate one reading. The following diagram demostrates the method of Average using 4 samples per reading.
Page 130
DAQ-9600 Series User Manual Press the key to enter the Average Window Method menu. F3 (WinMethod) Average window defines the threshold for when the digital key to select average data is updated again. When the data falls in the Average Window range between TH and TL, the Average keeps processing.
CONFIGURATION MENUS Log Menu Press the Log key on the front panel to enter the Background Log menu, which allows user to perform Capture function, which captures screenshot of hardcopy, or to operate ScanData, which saves data log of scanned readings into installed USB disk. Before performing Log functions, be aware of the supported USB disk as following: Note...
Page 132
DAQ-9600 Series User Manual Scan Data 1. Press the Log PARA (F1) key to select ScanData. Steps 2. Press the Logging (F2) key to activate if scanned readings data will be saved into the inserted USB disk automatically. Selecting “Off ” will not automatically save data into the USB disk and instead require manual operation for saving data.
Page 133
CONFIGURATION MENUS 5. Press the SaveRead (F6) key to perform data log of scanned readings saving into installed USB disk manually. Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com 127 rue de Buzenval BP 26 - 92380 Garches...
DIGITAL I/O Digital I/O Overview The Digital I/O port contains 1 pin for External Trigger Input Background and 4 pins for Alarm Output. When external trigger pulse is received by the external trigger input pin, the designated channel will be triggered accordingly. In terms of the 4 alarm output pins, anyone of the 4 pins can be assigned to anyone of the input channels to trigger external LED light, Relay control or send a TTL-compatible pulse to...
Page 136
DAQ-9600 Series User Manual Pin 1-4 are Output TTL-compatible pins, Pin1-4 which are selectable for TTL logic Hi or Lo alarm outputs. Pins output wiring diagram EOM (End Of Measurement) signal Output. Pin5 Activates when compare measurement is over. It is also available in other measurements.
DIGITAL I/O Application: Alarm Output The alarm output pins of Digital I/O port located on the rear Background panel, which send a TTL-compatible alarm output, can trigger the connected external alarm devices like sirens and LED lights. Anyone of the 4 alarm output pins can be assigned to anyone of the input channels to trigger external devices or send a TTL-compatible pulse to control system.
Page 138
DAQ-9600 Series User Manual Press the Alarm (F1) key to select an alarm limit(s) mode for the select channel. OFF Alarm condition is disabled for select channel. High+ Both High and Low limits of Alarm condition are activated.
DIGITAL I/O Application: External Trigger The external trigger uses the digital I/O pin for manual Background triggering of the DAQ-9600. To trigger the DAQ-9600 a pulse of ≥10μs is required. Connect the external trigger signal to the specific pins of Signal Digital I/O port located on the rear panel.
DAQ-9600 Series User Manual YSTEM & FIRMWARE View System Info ............... 141 Firmware Update ............... 142 Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com...
SYSTEM & FIRMWARE View System Info View system information including Vendor, Model Name, Background Serial Number, Master Firmware and Slave Firmware. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Security&Info –...
DAQ-9600 Series User Manual Firmware Update This section is for updating the latest firmware. Background 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Cali&Update - Firmware field.
Page 143
SYSTEM & FIRMWARE Prior to update, please rename the Note downloaded firmware files as below: Master file: M_IMAGE.bin Slave file: S_IMAGE.bin 1. Press the F5 (Enter) key or Knob key first, the qualified firmware version will show then. Note: If flash drive has no update files, it will show as the figure below.
Page 144
DAQ-9600 Series User Manual ENU SETTING Configure System ............... 145 Beep Setting ................145 Key Sound Setting ..............146 Date Setting ................147 Time Setting ................148 TimeSync Setting ..............149 Save and Load Parameters ............150 Copy Parameters To USB ............155 Copy Parameters From USB ............
MENU SETTING Configure System Beep Setting Enable or Disable Beep Sound. Background 1. Press the Menu key, the System Step configuration menu appears. 2. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to land on the ON option.
DAQ-9600 Series User Manual Key Sound Setting Enable or Disable Key Sound. Background 1. Press the Menu key, the System Step configuration menu appears. And then press the NEXT key repeatedly or scroll the Knob key to move to the Key Sound field.
MENU SETTING Date Setting Manually adjust date for system or automatically set date Background via TimeSync setting. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Date/Time - Date field.
DAQ-9600 Series User Manual Time Setting Manually adjust time for system or automatically set time Background via TimeSync setting. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Date/Time - Time field.
MENU SETTING TimeSync Setting TimeSync is only available when connecting to internet Background with appropriate network setting. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Date/Time - TimeSync field.
Last Update Time is Display the currently standard time. Save and Load Parameters The DAQ-9600 can save several instrument settings, which Background include the state, function, I/O and range settings. The Load function makes the saved settings or default setting to be recalled at the next power up or immediately.
Page 151
MENU SETTING Save Parameter Save&Load Select a 1. Press the F5 (Enter) key or Knob Group key to open the dropdown menu. 2. Scroll the Knob key or pressing +/- keys followed by pressing the F5 (Enter) key or Knob key to confirm the group selection.
Page 152
DAQ-9600 Series User Manual 4. Press the F2 (Backspace) key to clear default words. 5. Use the Left/Right and +/- keys or scroll the Knob key to move the cursor to desired word followed by pressing the F5 (Input) key or Knob key to input the word.
Page 153
MENU SETTING Select a 1. Press the F5 (Enter) key or Knob Group key to open the dropdown menu. 2. Scroll the Knob key or press +/- keys followed by pressing the F5 (Enter) key or Knob key to confirm the group selection.
Page 154
DAQ-9600 Series User Manual 5. Scroll the Knob key or press +/- keys followed by pressing the F5 (Enter) key or Knob key to confirm the action selection. 6. Press the F5 (Enter) key or Knob key to confirm the action selection.
MENU SETTING Copy Parameters To USB This section introduces how to copy the parameters of Background DAQ-9600 to the connected USB disk. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Copy To USB field.
USB completely. Copy Parameters From USB This section introduces how to recall the saved parameters Background from the connected USB disk to DAQ-9600. 1. Press the Menu key, the System Step configuration menu appears. And...
Page 157
Press F4 (OK) key to load parameters to DAQ-9600. 6. The prompt message indicates the selected parameters is loaded from the connected USB disk to DAQ-9600. Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax.
DAQ-9600 Series User Manual Calibration Setting This section mainly provides several calibrations for Background frequency, DC gain and DMM. Note that only the certified technician can operate the calibration procedure. Refer to the qualified personnel for more details when necessary.
Page 159
MENU SETTING Frequency Enable or disable frequency compensation Frequency Compensate (the value indicates the compensation Calibration (1.005000) coefficient; default: Factory calibration value) Check the box to enable: Frequency = Original Frequency x Compensate Coefficient Uncheck the box to disable: Frequency = Original Frequency Input 1.
DAQ-9600 Series User Manual Firmware Update This section is for updating the latest firmware. Background 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Cali&Update - Firmware field.
Page 161
MENU SETTING 1. Press the F5 (Enter) key or Knob key first, the qualified firmware version will show then. Note: If flash drive has no update files, it will show as the figure below. 2. Press the NEXT key or scroll Knob key to move to the Update followed by pressing the F5 (Enter) key or Knob key to Start update.
DAQ-9600 Series User Manual Security Setting This section is to change the password and enable or Background disable Lan password. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Security&Info –...
Page 163
MENU SETTING 4. Press the F4 (OK) key or Knob key to enter the Security page. Enable or disable password Security Lan Password requirement for Lan web and telnet Enable Control. Check / Uncheck Enter the old password Old Password Enter the new password New Password Enter the new password again...
DAQ-9600 Series User Manual View System Info View system information including Vendor, Model Name, Background Serial Number, Master Firmware and Slave Firmware. 1. Press the Menu key, the System Step configuration menu appears. And press the NEXT key repeatedly or scroll the Knob key to move to the Security&Info –...
MENU SETTING Configure Display Brightness Setting Backlight brightness adjustment Background 1. Press the Menu key followed by Step pressing the Page Down key repeatedly until the Display configuration menu appears. 2. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define digit.
DAQ-9600 Series User Manual Auto Off Setting Enable or disable automatic brightness adjustment Background 1. Press the Menu key followed by Step pressing the Page Down key repeatedly until the Display configuration menu appears. 2. Press the NEXT key repeatedly or scroll the Knob key to move to the BackLight - AutoOff field.
MENU SETTING 4. Press the F5 (Enter) key or Knob key to confirm the ON option for AutoOff. Auto Off Time Setting Set the duration before automatic brightness adjustment. Background When the machine has been idle for the set duration, the screen will change to automatic brightness adjustment.
Page 168
DAQ-9600 Series User Manual 3. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define minutes. Also, you can press Number keys to directly input a specific minutes. 4. Press the F5 (Enter) key or Knob key to confirm the input minutes for Auto Off Time.
MENU SETTING 1ST Color Setting Set the theme color of 1ST display Background 1. Press the Menu key followed by Step pressing the Page Down key repeatedly until the Display configuration menu appears. 2. Press the NEXT key repeatedly or scroll the Knob key to move to the Font Color –...
DAQ-9600 Series User Manual 4. Press the F5 (Enter) key or Knob key to confirm the selected color. The following figure demonstrates the Display result defined yellow color for 1ST display. Math Color Setting Set the theme color of Math functions Background 1.
Page 171
MENU SETTING 2. Press the NEXT key repeatedly or scroll the Knob key to move to the Font Color – Math Color field. 3. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to select desired color for Math display.
DAQ-9600 Series User Manual Display Mode Setting Enable or disable if time info or user-defined text is shown Background in the 1ST display only when MathDisp is off. 1. Press the Menu key followed by Step pressing the Page Down key repeatedly until the Display configuration menu appears.
Page 173
MENU SETTING Time display 1. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to select the Time option. 2. Press the F5 (Enter) key or Knob key to confirm the Time option.
DAQ-9600 Series User Manual Additional lnfo Setting Enable or disable the additional information display. Background 1. Press the Menu key followed by Step pressing the Page Down key repeatedly until the Display configuration menu appears. 2. Press the NEXT key repeatedly or scroll the Knob key to move to the Other Option –...
Page 175
MENU SETTING Take the Strain measurement with MX+B calculation for Display result example as the figure below, we can clearly recognize the colors with info as follows. Offset Value Info is outlined by blue frame. Auto Zero Info is outlined by white frame. ...
DAQ-9600 Series User Manual Language Setting Select language for user interface display. Background 1. Press the Menu key followed by Step pressing the Page Down key repeatedly until the Display configuration menu appears. 2. Press the NEXT key repeatedly or scroll the Knob key to move to the Other Option –...
Page 177
MENU SETTING English 繁體中文 (Traditional Chinese) Options 简体中文 (Simplified Chinese) Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com 127 rue de Buzenval BP 26 - 92380 Garches...
DAQ-9600 Series User Manual EMOTE CONTROL LINE RATING Mini GPIB 50/60Hz 50VA MAX. FUSE LINE 100V 250V 120V T0.125A 220V 240V Disconnect power cord and test leads before replacing fuse. For continued fire protection , use specified line fuse. Digital I/O...
REMOTE CONTROL Configure Interface Return to Local Control Mode When the unit is in remote control mode, the RMT icon Background above the main display can be seen. When this icon is not displayed, it indicates that the unit is in local control mode. In order to switch back to the Local control mode (front panel operation), press the Shift key.
DAQ-9600 Series User Manual 3. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to land on the desired SCPI ID Identity option. 4. Press the F5 (Enter) key or Knob key again to confirm the desired...
Page 181
REMOTE CONTROL 2. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to land on the USB option. 3. Press the F5 (Enter) key or Knob key to select the USB option. 4.
Page 182
DAQ-9600 Series User Manual 5. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to land on the desired USB Protocol option. 6. Press the F5 (Enter) key or Knob key again to confirm the USB Protocol option.
Page 183
REMOTE CONTROL 9. Press the F5 (Enter) key or Knob key again to confirm the selected option of EndOfLine field. 10. Press the F4 (NEXT) key repeatedly or scroll the Knob key to move to the Separation field. 11. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to land on the desired option...
Page 184
DAQ-9600 Series User Manual 12. Press the F5 (Enter) key or Knob key again to confirm the selected option of Separation field. 13. Connect the USB cable to the rear panel terminal (upper port). Tél. 01 47 95 99 45 e-mail : tem@es-france.com...
CDC or TMC USB class, install the appropriate CDC or TMC USB driver included on the User Manual CD. USBCDC: The USB port on the DAQ-9600 will appear as a virtual COM port to a connected PC. USBTMC: The DAQ-9600 can be controlled using National Instruments NI-Visa software*.
DAQ-9600 Series User Manual Configure GPIB Interface 24 Pin female GPIB port GPIB Configuration Connector 0-30(default 15) Address 1. Press the Menu key, and then Step the Page Down key repeatedly until the Interface configuration menu appears. 2. Press the F5 (Enter) key or...
Page 187
REMOTE CONTROL 5. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define GPIB Address. Also, you can press Number keys to directly input a specific digit. 6. Press the F5 (Enter) key or Knob key again to confirm the input digit for GPIB Address.
Page 188
DAQ-9600 Series User Manual 7. Connect the GPIB cable to the mini GPIB port from the rear panel of DAQ-9600. Pin Signal Pin Signal GPIB Pin Assignment Data I/O 1 Data I/O 2 14 Data I/O 6 Data I/O 3...
REMOTE CONTROL Activate Ethernet Interface Speed 10BaseT/100BaseTx Overview 1. Press the Menu key, and then Ethernet(LAN) the Page Down key repeatedly port activation until the Interface configuration menu appears. 2. Press the F5 (Enter) key or Knob key followed by scrolling Knob key or pressing +/- keys to land on the LAN option.
DAQ-9600 Series User Manual LAN Connect Delay Time User is able to set a delay time in second(s) for LAN Background connection when booting up the DAQ-9600. 1. Press the Menu key, and then LAN Connect the Page Down key repeatedly...
Ethernet to the new configuration settings. New Ethernet configuration settings are only updated after the DAQ-9600 has been reset. NOTE Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests &...
DAQ-9600 Series User Manual Configure Ethernet Interface to DHCP The DAQ-9600 supports DHCP to have an IP address Background and other configuration parameters automatically assigned by a DHCP server. 1. Press the Menu key, and then DHCP the Page Down key repeatedly...
REMOTE CONTROL Configure Ethernet IP The DAQ-9600 supports manually setting of IP addresses, Background including the subnet mask, gateway, DNS1 and DNS2. The IP Address Setup can only be edited if DHCP is off. NOTE 1. Press the Menu key, and then...
Page 194
DAQ-9600 Series User Manual 3. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define IP Address. Also, you can press Number keys to directly input a specific digit. 4. Press the F5 (Enter) key or Knob key to confirm the input digit for IP1 Address.
Page 195
REMOTE CONTROL 7. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define Subnet. Also, you can press Number keys to directly input a specific digit. 8. Press the F5 (Enter) key or Knob key again to confirm the input digit for S1.
Page 196
DAQ-9600 Series User Manual 11. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define Gateway. Also, you can press Number keys to directly input a specific digit. 12. Press the F5 (Enter) key or Knob key to confirm the input digit for G1.
Page 197
REMOTE CONTROL 15. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define DNS1. Also, you can press Number keys to directly input a specific digit. 16. Press the F5 (Enter) key or Knob key again to confirm the input digit for D11.
Page 198
DAQ-9600 Series User Manual 19. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define DNS2. Also, you can press Number keys to directly input a specific digit. 20. Press the F5 (Enter) key or Knob key again to confirm the input digit for D21.
REMOTE CONTROL Configure Protocol The DAQ-9600 supports 3 Ethernet protocol to used, Background including the Web browser, Telnet and TCP. 1. Press the Menu key, and then the Page Down key repeatedly Configuration until the Lan Setup configuration menu appears.
Page 200
DAQ-9600 Series User Manual 4. Press the F5 (Enter) key or Knob key to confirm the Web ON option. 5. Press the F4 (NEXT) key Telnet repeatedly or scroll the Knob Configuration key to move to the Protocol – Telnet field.
Page 201
REMOTE CONTROL 7. Press the F5 (Enter) key or Knob key to confirm the Telnet ON option. 8. Press the F4 (NEXT) key Telnet Port repeatedly or scroll the Knob Configuration key to move to the Protocol – Telnet Port field. 9.
Page 202
DAQ-9600 Series User Manual 10. Press the F5 (Enter) key or Knob key to confirm the input digit for Telnet Port. Range 1024~65535(Default = 5024) 11. Press the F4 (NEXT) key Telnet ECHO repeatedly or scroll the Knob Configuration key to move to the Protocol –...
Page 203
REMOTE CONTROL 13. Press the F5 (Enter) key or Knob key again to confirm the Telnet ECHO ON option. 14. Press the F4 (NEXT) key repeatedly or scroll the Knob Configuration key to move to the Protocol - TCP field. 15.
Page 204
DAQ-9600 Series User Manual 18. Use the Left/Right keys to move the cursor followed by scrolling Knob key or pressing +/- keys to define TCP Port. Also, you can press Number keys to directly input a specific digit. Range 1024~65535(Default = 5025) 19.
Remote Terminal Session (Telnet / TCP) A terminal application can be used to remotely control Background the DAQ-9600 via the Telnet or TCP protocol. Operation 1. Establish a connection via the Ethernet port. 2. Open a terminal program such as Hyper Terminal and enter the IP address and port number of the DAQ-9600.
1. Configure the LAN interface and connect the Step 1 - DAQ-9600 to the LAN.. Connection 2. Enter the IP address of the DAQ-9600 in the address field of the web browser. 3. The web control Welcome Page appears. DAQ-9600 Welcome Page 1.
Page 207
REMOTE CONTROL 2. The control panel display, which is identical to that of the physical DAQ-9600, appears. 3. Set the basic operations and monitor measurement Step 2-1 - readings, and press apply button to enable the control Configuration settings when parameters have been changed.
Page 208
DAQ-9600 Series User Manual Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com 127 rue de Buzenval BP 26 - 92380 Garches...
Page 209
REMOTE CONTROL 3. The View & Modify Configuration page allows you to: View the instrument name, firmware revision of the Ethernet card, IP address and MAC address. Set the IP address to DHCP or static. Configure the module host name and the parameters of TCP &...
DAQ-9600 Series User Manual Command Syntax Partial compatibility Compatible IEEE488.2 Standard Partial compatibility SCPI, 1994 SCPI (Standard Commands for Programmable Instruments) Command commands follow a tree-like structure, organized into nodes. Structure Each level of the command tree is a node. Each keyword in a SCPI command represents each node in the command tree.
Page 211
REMOTE CONTROL Long form CONFigure:DIODe CONFIGURE:DIODE Configure:diode Short form CONF:DIOD conf:diod Commands that contain square brackets indicate that the Square contents are optional. The function of the command is the Brackets same with or without the square bracketed items, as shown below.
Page 212
This parameter can be used in place of any numerical parameter where indicated. For queries, it will return the default value allowed for the particular setting. The DAQ-9600 automatically sets the command parameter to Automatic the next available value. parameter range...
DAQ-9600 Series User Manual Other Commands ABORt Aborts a measurement in progress form a scan, returning the instrument to the trigger idle state. ●If a scan is in progress when the command is received, the scan will not be completed and you cannot resume the scan from where it left off. Note that if you initiate a new scan, all readings are cleared from reading memory.
REMOTE CONTROL INITiate[:IMMediate] Changes the state of the triggering system from "idle" to "wait-for-trigger", and clears the previous set of measurements from reading memory. Measurements will begin when the specified trigger conditions are satisfied following the receipt of INIT command. Example: CONF:VOLT:DC 10,(@101, 107) TRIG:SOUR BUS...
Page 222
DAQ-9600 Series User Manual Reads and erases measurements from reading memory up to the specified <reading_number>. The measurements are read and erased from the reading memory starting with the oldest measurement first. Query Syntax: R? [<reading_number>] Parameter: <reading_number> (1 ~ 100,000)
REMOTE CONTROL READ? Changes the state of the triggering system from "idle" to "wait-for-trigger". Scanning will begin when the specified trigger conditions are satisfied following the receipt of the READ? command. Readings are then sent to reading memory and the instrument's output buffer. Example: CONF:VOLT:DC 10,(@101,102) TRIG:SOUR EXT...
DAQ-9600 Series User Manual UNIT:TEMPerature Specifies the units °C (Celsius), °F (Fahrenheit), or K (Kelvin) to be used for all temperature measurements. Syntax: UNIT:TEMPerature <unit>[,(@<ch_list>)] Query Syntax: UNIT:TEMPerature? [(@<ch_list>)] Parameter: <unit> (C | F | K) Return parameter: C | F | K...
REMOTE CONTROL CALCulate:AVERage:{AVERage|MAXimum|MINimum|PTPeak|SDEViation}? Returns the average, maximum, minimum, peak-to-peak or standard deviation recorded values. Query Syntax: CALCulate:AVERage:{AVERage|MAXimum|MINimum|PTPeak|SDEViation}? [(@<ch_list>)] Return parameter: <NRf> Example: CALC:AVER:MAX? (@101,102,108) Returns: +4.13148354E+00,+4.15167734E+00,+4.85178821E+00 ●In this example, you can replace the MAX node with AVER, MIN, PTP or SDEV.
DAQ-9600 Series User Manual CALCulate:AVERage:{MAXimum|MINimum}:TIME? Returns the time that the maximum or minimum reading was taken on the selected channels during the scan (in full time and date format). Query Syntax: CALCulate:AVERage:{MAXimum|MINimum}:TIME? [(@<ch_list>)] Return parameter: <time> (yyyy,mm,dd,hh,mm,ss.sss) Example: CALC:AVER:MIN:TIME? (@101,102) Returns: 2023,03,01,07,26,20.146,2023,03,01,07,26,29.023...
REMOTE CONTROL CALCulate:LIMit:{LOWer|UPPer}:STATe Enables or disables the lower and upper alarm limits on the specified channels during a scan. Syntax: CALCulate:LIMit:{LOWer|UPPer}:STATe {OFF|ON}[,(@<ch_list>)] Query Syntax: CALCulate:LIMit:{LOWer|UPPer}:STATe? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0=OFF, 1=ON) Example: CALC:LIM:LOW 2(@101,102) CALC:LIM:LOW:STAT ON,(@101,102)
DAQ-9600 Series User Manual CALCulate:MATH A computed channel performs mathematical operation on the readings from measurement channels, or other computed channels list. Syntax: CALCulate:MATH <expression>,(@<computed_ch_list>) Query Syntax: CALCulate:MATH? (@<computed_ch_list>) Parameter: Computation type Mathematical operation (<expression>) Basic math (@ch1+@ch2) Subtract (@ch1-@ch2)
REMOTE CONTROL CALCulate:SCALe:OFFSet:NULL Makes an immediate null measurement on the specified channels and stores it as the offset (B) for subsequent measurements. Syntax: CALCulate:SCALe:OFFSet:NULL [(@<ch_list>)] Parameter: [None] Example: CALC:SCAL:FUNC SCAL CALC:SCAL:OFFS:NULL (@101) CALCulate:SCALe:PERCent Sets or returns the reference value for the PCT function. Syntax: CALCulate:SCALe:PERCent {<reference>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: CALCulate:SCALe:PERCent? [{(@<ch_list>)|MIN|MAX|DEF}]...
DAQ-9600 Series User Manual CALCulate:SCALe:REFerence:AUTO Enables or disables automatic reference selection for the scaling functions. Syntax: CALCulate:SCALe:REFerence:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: CALCulate:SCALe:REFerence:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) ON: the first measurement made is used as the reference for all subsequent measurements, and automatic reference selection is disabled.
REMOTE CONTROL CALCulate:SCALe:UNIT To specify the custom unit up to three characters (for example: RPM, PSI, or °C) for scaled measurements. Syntax: CALCulate:SCALe:UNIT "<string>"[,(@<ch_list>)] Query Syntax:CALCulate:SCALe:UNIT? [(@<ch_list>)] " " Parameter: <string> , max length = 3 characters Return parameter: "<string>" Example: CALC:SCAL:UNIT "BAR"...
DAQ-9600 Series User Manual CONFigure:CAPacitance Configures the channels for Capcitance measurements. Syntax: CONFigure:CAPacitance [{<range>|AUTO|MIN|MAX|DEF},[{<resolution>|MIN|MAX|DEF},]](@<ch_l ist>) Parameter: <range> (1nF | 10nF | 100nF | 1μF | 10μF | 100μF); DEF: AUTO Example: CONF:CAP 10e-7,(@101) CONFigure:CURRent:{AC|DC} Configures the channels for AC and DC current measurements.
REMOTE CONTROL DATA:POINts? Returns the total number of readings currently saved in reading memory from a scan. Return parameter: <NR1> Example: DATA:POIN? Returns: +10 ●You can store up to 100,000 measurements in the reading memory. DATA:POINts:EVENt:THReshold Sets or returns the threshold for event number of measurement. Syntax: DATA:POINts:EVENt:THReshold <num_rdgs>...
DAQ-9600 Series User Manual DATA:REMove? Reads and erases measurements from reading memory up to the specified <num_rdgs>. The measurements are read and erased from the reading memory starting with the oldest measurement first. Query Syntax: DATA:REMove? <num_rdgs>,[WAIT] Parameter: <num_rdgs> (1 ~ 100,000)
DAQ-9600 Series User Manual DISPlay Enables (On) or disables (Off) front panel display. When disabled, the entire front panel display turns black and time stamp is displayed. Syntax: DISPlay {OFF|ON} Query Syntax: DISPlay? Parameter: 0 | 1 | OFF | ON...
REMOTE CONTROL FORMat:READing:ALARm Enables (On) or disables (Off) the inclusion of alarm information in the reading format. Syntax: FORMat:READing:ALARm {OFF|ON} Query Syntax: FORMat:READing:ALARm? Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: FORM:READ:ALAR ON FORMat:READing:CHANnel...
DAQ-9600 Series User Manual FORMat:READing:TIME:TYPE Selects the time format (absolute or relative) for time stamp returned when FORMat:READing:TIME is enabled. Syntax: FORMat:READing:TIME:TYPE {ABSolute|RELative} Query Syntax: FORMat:READing:TIME:TYPE? Parameter: ABSolute | RELative Return parameter: ABS | REL Example: FORM:READ:TIME:TYPE ABS ●Relative format - shows the time since the start of the scan.
REMOTE CONTROL HCOPy:SDUMp:DATA? Executes TFT LCD screenshot action. Returns the front panel display image ("screen shot"). Returns a count of data streaming by the image file format of BMP. Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax.
DAQ-9600 Series User Manual MEASure Commands MEASure:CAPacitance? Configures the channels for capacitance measurements and immediately sweeps through the specified channels one time (independent of the present scan list). The results are sent directly to reading memory and the instrument's output buffer.
REMOTE CONTROL MEASure:DIODe? Configures the channels for Diode current measurements and immediately sweeps through the specified channels one time (independent of the present scan list). The results are sent directly to reading memory and the instrument's output buffer. Query Syntax: MEASure:DIODe? (@<ch_list>) Parameter: [None] Return parameter: <NRf>...
DAQ-9600 Series User Manual MEASure:{RESistance|FRESistance}? Configures the channels for 2-Wire and 4-Wire resistance measurements and immediately sweeps through the specified channels one time (independent of the present scan list). The results are sent directly to reading memory and the instrument's output buffer.
REMOTE CONTROL MEASure:STRain:{FULL|HALF}:BENDing? Configures the channels for full and half bending bridge strain gage measurements and immediately sweeps through the specified channels one time (independent of the present scan list). The results are sent directly to reading memory and the instrument's output buffer. Query Syntax: MEASure:STRain:{FULL|HALF}:BENDing? [{<gage_factor>|MIN|MAX|DEF},[{<range>|MIN|MAX|DEF},[{<resolution>| MIN|MAX|DEF},]]](@<ch_list>)
DAQ-9600 Series User Manual MEASure:STRain:FULL:BENDing:POISson? Configures the channels for full bending poisson bridge strain gage measurements and immediately sweeps through the specified channels one time (independent of the present scan list). The results are sent directly to reading memory and the instrument's output buffer.
REMOTE CONTROL MEASure:TEMPerature? Configures the channels for temperature measurements and immediately sweeps through the specified channels one time (independent of the present scan list). The results are sent directly to reading memory and the instrument's output buffer. Query Syntax: MEASure:TEMPerature? <probe_type>,[{<type>|DEF},[{<resolution>|MIN|MAX|DEF},]](@<ch_list>) Parameter: <probe type>...
DAQ-9600 Series User Manual MMEMory Commands MMEMory:FORMat:READing:CHEAder Specifies the content of each column header to be either the channel number (NUMber) or the channel's user-defined label (LABel). Syntax: MMEMory:FORMat:READing:CHEAder {NUMber|LABel} Query Syntax: MMEMory:FORMat:READing:CHEAder? Parameter: NUMber | LABel Return parameter: NUM | LAB...
REMOTE CONTROL MMEMory:FORMat:READing:RLIMit:COUNt Sets the row limits count when MMEMory:FORMat:READing:RLIMit ON is set. Syntax: MMEMory:FORMat:READing:RLIMit:COUNt {<number>|MIN|MAX|DEF} Query Syntax: MMEMory:FORMat:READing:RLIMit:COUNt? [{MIN|MAX|DEF}] Parameter: <number> (65536 | 1048576); DEF: 65536 Return parameter: <NR1> Example: MMEM:FORM:READ:RLIM:COUN 10000 MMEMory:LOG[:ENABle] Enables (On) or disables (Off) logging of the scanned memory readings to a USB drive connected to the front panel USB host port.
DAQ-9600 Series User Manual Output Commands OUTPut:ALARm:CLEar:ALL Clears the state of all four alarm output lines. Parameter: [None] Example: OUTP:ALAR:CLE ●You can manually clear the output lines at any time (even during a scan) and the alarm data in reading memory is not cleared. However, data is cleared when you initiate a new scan.
REMOTE CONTROL OUTPut:ALARm{1|2|3|4}:SOURce Assigns one of four alarm numbers to report any alarm conditions on the specified multiplexer or digital channels. On the digital modules, you can configure the instrument to generate an alarm when a specific bit pattern or bit pattern change is detected on a digital input channel or when a specific count is reached on a totalizer channel.
DAQ-9600 Series User Manual OUTPut:ALARm:SLOPe Configures the level for all four alarm output lines that indicates an alarm, either falling edge (NEG - 0 V), or rising edge (POS - 3.3 V). Syntax: OUTPut:ALARm:SLOPe {POSitive|NEGative} Query Syntax: OUTPut:ALARm:SLOPe? Parameter: POSitive | NEGative...
REMOTE CONTROL ROUTe Commands ROUTe:CHANnel:ADVance:SOURce Selects the source of signal that advances to the next channel in the scan list when scanning with an external DMM (internal DMM disabled). When the channel advance signal is received, the instrument opens the currently selected channel and closes the next channel in the scan list.
DAQ-9600 Series User Manual ROUTe:CHANnel:DELay:AUTO Enables (On) or disables (Off) an automatic channel delay on the specified channels. If enabled, the instrument determines the delay based on function, range, integration time, and AC filter setting. Syntax: ROUTe:CHANnel:DELay:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: ROUTe:CHANnel:DELay:AUTO? [(@<ch_list>)]...
REMOTE CONTROL ROUTe:CHANnel:LABel Assigns a user-defined label to the specified channels. Syntax: ROUTe:CHANnel:LABel "<label>",(@<ch_list>) Query Syntax: ROUTe:CHANnel:LABel? [{USER|FACtory},](@<ch_list>) Parameter:"<label>", max length = 30 characters Return parameter: "<label>" USER = Read the user-defined label on the specified channel. FACTory = Read the factory-default label on the specified channel. Example: ROUT:CHAN:LAB "test",(@101,103) ROUT:CHAN:LAB? USER,(@101,103)
DAQ-9600 Series User Manual ROUTe:CLOSe Closes the specified channels on a multiplexer or switch module. On the multiplexer modules, if any channel on the module is defined to be part of the scan list, attempting to send this command will result in an error.
REMOTE CONTROL ROUTe:DONE? Returns the status of all relay operations on modules that not involved in the scan and returns a 1 when finished (even during a scan). Return parameter: 0 | 1, (0 = Unfinished, 1 = finished) Example: ROUT:DONE? Returns: 1 ROUTe:MONitor...
DAQ-9600 Series User Manual ROUTe:MONitor:DATA? Reads the monitor data from the selected channel. It returns the reading only; the units, time, channel, and alarm information are not returned (the FORMat:READing commands do not apply to monitor readings). Return parameter: <NRf>...
REMOTE CONTROL ROUTe:MONitor:STATe Enables (On) or disables (Off) the Monitor mode. The Monitor mode is equivalent to making continuous measurements on a single channel with an infinite scan count. Only one channel can be monitored at a time but you can change the channel being monitored at any time. Syntax: ROUTe:MONitor:STATe {OFF|ON} Query Syntax: ROUTe:MONitor:STATe? Parameter: 0 | 1 | OFF | ON...
DAQ-9600 Series User Manual ROUTe:OPEN Opens the specified channels on a multiplexer or switch module. On the multiplexer modules, if any channel on the module is defined to be part of the scan list, attempting to send this command will result in an error.
REMOTE CONTROL ROUTe:SCAN:SIZE? Returns the number of channels in the scan list as defined by the ROUTe:SCAN command. Return parameter: <NR1> Example: ROUT:SCAN (@101:105) ROUT:SCAN:SIZE? Returns: +5 ●The present scan list is stored in non-volatile memory and will be retained when power is turned off.
REMOTE CONTROL [SENSe:]AVERage:STATe Enable(On) or disable(Off) the digital filter function state. Syntax: [SENSe:]AVERage:STATe {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]AVERage:STATe? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: AVER:STAT ON ●If NPLC >= 7.2k/s, the filter function will be disabled.
REMOTE CONTROL SENSe CURRent Commands [SENSe:]CURRent:AC:BANDwidth Sets or returns the ac filter bandwith for AC current measurements. Syntax: [SENSe:]CURRent:AC:BANDwidth {<freq>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]CURRent:AC:BANDwidth? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <freq> (3 | 20 | 200Hz); DEF: 20Hz Return parameter: <NRf> Example: CONF:CURR:AC (@121) CURR:AC:BAND 3 CURR:AC:BAND? Returns: +3.00000000E+00 [SENSe:]CURRent:{AC|DC}:RANGe...
DAQ-9600 Series User Manual [SENSe:]CURRent:{AC|DC}:RANGe:AUTO Enables or disables autoranging for AC and DC current measurements. Syntax: [SENSe:]CURRent:{AC|DC}:RANGe:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]CURRent:{AC|DC}:RANGe:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON)
REMOTE CONTROL [SENSe:]CURRent[:DC]:APERture Enables the aperture mode and sets the integration time in seconds (called aperture time) for DC current measurements. Syntax: [SENSe:]CURRent[:DC]:APERture {<seconds>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]CURRent[:DC]:APERture? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <seconds> (20μs ~ 1s); DEF: 100ms Return parameter: <NRf> Example: CONF:CURR:DC (@121) CURR:APER 0.1 CURR:APER? Returns: +1.00000000E-01...
Page 272
DAQ-9600 Series User Manual [SENSe:]CURRent[:DC]:NPLCycles Sets or returns the integration time in number of power line cycles (PLCs) for DC current measurements. Where one PLC is equal to 16.6 milliseconds. Syntax: [SENSe:]CURRent[:DC]:NPLCycles {<PLCs>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]CURRent[:DC]:NPLCycles? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <PLCs> (0.0016 | 0.0032 | 0.0042 | 0.0083 | 0.0125 | 0.025 | 0.05 | 0.15 | 0.6 | 1 | 3 | 12);...
Page 273
REMOTE CONTROL [SENSe:]DIODe:ZERO:AUTO Enables or disables the autozero mode for diode measurements. Syntax: [SENSe:]DIODe:ZERO:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]DIODe:ZERO:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: CONF:DIOD (@101) DIOD:ZERO:AUTO ON SENSe FREQuency Commands [SENSe:]{FREQuency|PERiod}:APERture...
Page 274
DAQ-9600 Series User Manual [SENSe:]{FREQuency|PERiod}:RANGe:LOWer Sets or returns the ac filter bandwith of frequency and period measurements. Syntax: [SENSe:]{FREQuency|PERiod}:RANGe:LOWer {<freq>|MIN|MAX|DEF}[,(@<ch_list>) Query Syntax: [SENSe:]{FREQuency|PERiod}:RANGe:LOWer? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <freq> (3 | 20 | 200Hz); DEF: 20Hz Return parameter: <NRf> Example: CONF:FREQ (@101) FREQ:RANG:LOW 3 FREQ:RANG:LOW? Returns: +3.00000000E+00...
Page 275
REMOTE CONTROL [SENSe:]{FREQuency|PERiod}:VOLTage:RANGe Selects a fixed voltage range for frequency and period measurements. Syntax: [SENSe:]{FREQuency|PERiod}:VOLTage:RANGe {<range>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]{FREQuency|PERiod}:VOLTage:RANGe? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <range> (100mV | 1V | 10V | 100V | 400V); DEF: 10V Return parameter: <NRf> Example: CONF:FREQ (@101) FREQ:VOLT:RANG 0.1 FREQ:VOLT:RANG? Returns: +1.00000000E-01 [SENSe:]{FREQuency|PERiod}:VOLTage:RANGe:AUTO...
Page 276
DAQ-9600 Series User Manual [SENSe:]{RESistance|FRESistance}:APERture Enables the aperture mode and sets the integration time in seconds (called aperture time) for 2-wire and 4-wire resistance measurements. Syntax: [SENSe:]{RESistance|FRESistance}:APERture {<seconds>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]{RESistance|FRESistance}:APERture? [(@<ch_list>)|MIN|MAX|DEF}] Parameter: <seconds> (20μs ~ 1s); DEF: 100ms Return parameter: <NRf>...
Page 277
REMOTE CONTROL [SENSe:]{RESistance|FRESistance}:NPLCycles Sets or returns the integration time in number of power line cycles (PLCs) for 2-wire and 4-wire resistance measurements. Where one PLC is equal to 16.6 milliseconds. Syntax: [SENSe:]{RESistance|FRESistance}:NPLCycles {<PLCs>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]{RESistance|FRESistance}:NPLCycles? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <PLCs> (0.0016 | 0.0032 | 0.0042 | 0.0083 | 0.0125 | 0.025 | 0.05 | 0.15 | 0.6 | 1 | 3 | 12);...
Page 278
DAQ-9600 Series User Manual [SENSe:]{RESistance|FRESistance}:POWer:LIMit[:STATe] Enables or disables low-power for 2-wire and 4-wire resistance measurements. Syntax: [SENSe:]{RESistance|FRESistance}:POWer:LIMit[:STATe] {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]{RESistance|FRESistance}:POWer:LIMit[:STATe]? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON)
Page 279
REMOTE CONTROL [SENSe:]{RESistance|FRESistance}:RANGe:AUTO Enables or disables autoranging for 2-wire and 4-wire resistance measurements. Syntax: [SENSe:]{RESistance|FRESistance}:RANGe:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]{RESistance|FRESistance}:RANGe:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: CONF:FRES (@101) FRES:RANG:AUTO ON ●Autorange thresholds:...
Page 280
DAQ-9600 Series User Manual [SENSe:]STRain:APERture Enables the aperture mode and sets the integration time in seconds (called aperture time) for strain measurements. Syntax: [SENSe:]STRain:APERture {<seconds>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]STRain:APERture? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <seconds> (20μs ~ 1s); DEF: 100ms Return parameter: <NRf> Example: CONF:STR:DIR (@101) STR:APER 0.1...
Page 281
REMOTE CONTROL [SENSe:]STRain:EXCitation Specifies the excitation voltage applied to the bridge by an external DC voltage source. This value will be used to convert strain bridge measurements on the specified channel. Syntax: [SENSe:]STRain:EXCitation {<voltage>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]STRain:EXCitation? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <voltage> (1 ~ 12V); DEF: 5V Return parameter: <NRf>...
Page 282
DAQ-9600 Series User Manual [SENSe:]STRain:GFACtor Specifies the gage factor to be used to convert direct strain and strain bridge readings on the specified channel. Gage factor is defined as the ratio of the fractional change in resistance to the fractional change in length (strain) along the axis of the edge.
Page 283
REMOTE CONTROL [SENSe:]STRain:OCOMpensated Enables or disables offset compensation for strain measurements. Syntax: [SENSe:]STRain:OCOMpensated {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]STRain:OCOMpensated? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: CONF:STR:DIR (@101) STR:OCOM ON ●Applies only to resistance measurements on the 100 Ω...
Page 284
DAQ-9600 Series User Manual [SENSe:]STRain:RESistance This command specifies the gage ohm value to be used to convert direct strain measurements on the specified channel. Syntax: [SENSe:]STRain:RESistance {<gage_ohm>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]STRain:RESistance? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <gage_ohm> (80 ~ 1100Ω); DEF: 120Ω Return parameter: <NRf>...
Page 285
REMOTE CONTROL [SENSe:]STRain:UNSTrained:IMMediate This command immediately measures and stores the bridge offset voltages on the specified channel. Syntax: [SENSe:]STRain:UNSTrained:IMMediate [(@<ch_list>)] Parameter: [None] Example: CONF:STR:QUAR (@101) STR:UNST:IMM STR:UNST? Returns: -9.055960E-05 [SENSe:]STRain:VOLTage:RANGe Selects a fixed range for strain measurements. Syntax: [SENSe:]STRain:VOLTage:RANGe {<range>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]STRain:VOLTage:RANGe? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter:...
Page 286
DAQ-9600 Series User Manual [SENSe:]STRain:ZERO:AUTO Enables or disables the autozero mode for strain measurements. Syntax: [SENSe:]STRain:ZERO:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]STRain:ZERO:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON)
Page 287
REMOTE CONTROL [SENSe:]TEMPerature:APERture:ENABle Enables the setting of integration time in seconds (called aperture time) for temperature measurements. If aperture time mode is disabled , the integration time is set in PLC (power-line cycles). Syntax: [SENSe:]TEMPerature:APERture:ENABle {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:APERture:ENABle? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example:...
Page 288
DAQ-9600 Series User Manual [SENSe:]TEMPerature:RJUNction:SIMulated:AUTO:OFFSet Sets or returns junction reference temperature adjust value of thermocouple measurement which internal temperature is selected. Syntax: [SENSe:]TEMPerature:RJUNction:SIMulated:AUTO:OFFSet {<temperature>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:RJUNction:SIMulated:AUTO:OFFSet? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <temperature> (-20.00 ~ 20.00); DEF:0 Return parameter: <NRf>, where unit = ˚C...
Page 289
REMOTE CONTROL [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:USER:BETA Sets or returns the 2-wire and 4-wire RTD beta coefficient. Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:USER:BETA {<coefficient>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:USER:BETA? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <coefficient> (0.0~9.999999); DEF: 0 Return parameter: <NRf> Example: TEMP:TRAN:RTD:USER:BETA 0.10863 [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:USER:DELTa Sets or returns the 2-wire and 4-wire RTD delta coefficient. Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:USER:DELTa {<coefficient>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax:...
Page 290
DAQ-9600 Series User Manual [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:OCOMpensated Enables or disables offset compensation for temperature measurements. Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:OCOMpensated {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:OCOMpensated? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example:...
Page 291
REMOTE CONTROL [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:REFerence Enables (On) or disables (Off) the specified 2-wire and 4-wire RTD channels to be used as the reference channel for subsequent thermocouple measurements that specify an external reference source. Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:REFerence {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:REFerence? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: CONF:TEMP RTD,(@101)
Page 292
DAQ-9600 Series User Manual [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:PO Wer:LIMit[:STATe] Enables or disables low-power for 2-wire and 4-wire thermistor measurements. Syntax: [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:POWer:LIM it[:STATe] {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:POWer:LIM it[:STATe]? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON)
Page 293
REMOTE CONTROL [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:TYP Sets or returns the 2-wire and 4-wire thermistor sensor type. Syntax: [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:TYPE {<sensor_type>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:TYPE? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <sensor_type> (2.2k | 5k | 10k | USER); DEF: 5k Ω Ω Ω Ω Return parameter: +2000 | +5000 | +10000 | USER Example: TEMP:TRAN:THER:TYPE 2200 [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:USE...
Page 294
DAQ-9600 Series User Manual [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:USE R:BVALue Sets or returns the 2-wire and 4-wire thermistor b coefficient. Syntax: [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:USER:BVAL ue {<coefficient>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:USER:BVAL ue? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <coefficient> (0.0~9.9999); DEF: 0 Return parameter: <NRf> Example: TEMP:TRAN:FTH :USER:BVAL 0.003425 [SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:USE R:CVALue Sets or returns the 2-wire and 4-wire thermistor c coefficient.
Page 295
REMOTE CONTROL [SENSe:]TEMPerature:TRANsducer:TCouple:CHECk Enables or disables the thermocouple check feature to verify that your thermocouples are properly connected for measurements. When enabled, the instrument measures the resistance after each thermocouple measurement to ensure a proper connection. If an open connection is detected (greater than 5 kΩ...
Page 296
DAQ-9600 Series User Manual [SENSe:]TEMPerature:TRANsducer:TCouple:RJUNction:TYPE Selects the reference junction source for thermocouple measurements on the specified channels. Syntax: [SENSe:]TEMPerature:TRANsducer:TCouple:RJUNction:TYPE <reference>[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:TRANsducer:TCouple:RJUNction:TYPE? [(@<ch_list>)] Parameter: <reference> (INTernal | EXTeranl | FIXed) Return parameter: INT | EXT | FIX Example: CONF :TEMP TC,(@101)
Page 297
REMOTE CONTROL [SENSe:]TEMPerature:ZERO:AUTO Enables or disables the autozero mode for temperature measurements. Syntax: [SENSe:]TEMPerature:ZERO:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]TEMPerature:ZERO:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: CONF:TEMP TC,(@101) TEMP:ZERO:AUTO ON SENSe VOLTage Commands [SENSe:]VOLTage:AC:BANDwidth...
Page 298
DAQ-9600 Series User Manual [SENSe:]VOLTage:{AC|DC}:RANGe Selects a fixed range for AC and DC voltage measurements. Syntax: [SENSe:]VOLTage:{AC|DC}:RANGe {<range>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]VOLTage:{AC|DC}:RANGe? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <range>: AC: (100mV | 1V | 10V | 100V | 400V); DEF: AUTO DC: (100mV | 1V | 10V | 100V | 600V); DEF: AUTO Return parameter: <NRf>...
Page 299
REMOTE CONTROL [SENSe:]VOLTage[:DC]:APERture Enables the aperture mode and sets the integration time in seconds (called aperture time) for DC voltage measurements. Syntax: [SENSe:]VOLTage[:DC]:APERture {<seconds>|MIN|MAX|DEF}[,(@<ch_list>)] Query Syntax: [SENSe:]VOLTage[:DC]:APERture? [{(@<ch_list>)|MIN|MAX|DEF}] Parameter: <seconds> (20μs ~ 1s); DEF: 100ms Return parameter: <NRf> Example: CONF:DC (@101) VOLT:APER 0.1 VOLT:APER ? Returns: +1.00000000E-01...
Page 300
DAQ-9600 Series User Manual [SENSe:]VOLTage[:DC]:IMPedance:AUTO Enables or disables automatic input impedance mode for DC voltage measurements. Syntax: [SENSe:]VOLTage[:DC]:IMPedance:AUTO {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]VOLTage[:DC]:IMPedance:AUTO? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) OFF: The input impedance for DC voltage measurements is fixed at 10 MΩ...
Page 301
REMOTE CONTROL [SENSe:]VOLTage[:DC]:REFerence Enables (On) or disables (Off) the specified DC voltage channels to be used as the reference channel for subsequent strain bridge measurements that specify an external excitation reference voltage source (see [SENSe:]STRain:EXCitation:TYPE command). Syntax: [SENSe:]VOLTage[:DC]:REFerence {OFF|ON}[,(@<ch_list>)] Query Syntax: [SENSe:]VOLTage[:DC]:REFerence? [(@<ch_list>)] Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example:...
Page 302
DAQ-9600 Series User Manual STATus Report Commands STATus:ALARm:CONDition? Returns the total number of the Alarm Condition register. Return parameter: <NR1> (0 ~ 32767) Example: STAT:ALAR:COND? Returns: +16 ●A condition register continuously monitors the state of the instrument. Condition register bits are updated in real time; they are neither latched nor buffered.
Page 303
REMOTE CONTROL STATus:ALARm[:EVENt]? Returns the total number of the Alarm Event register. Return parameter: <NR1> Example: STAT:ALAR:EVEN? Returns: +7 ●An event register is a read-only register that latches events from the condition register. While an event bit is set, subsequent events corresponding to that bit are ignored.
Page 304
DAQ-9600 Series User Manual STATus:OPERation[:EVENt]? Returns the total number of the Operation Event register. Return parameter: <NR1> Example: STAT:OPER:EVEN? Returns: +786 ●An event register is a read-only register that latches events from the condition register. While an event bit is set, subsequent events corresponding to that bit are ignored.
Page 305
REMOTE CONTROL STATus:QUEStionable:ENABle Sets or returns bits in the Ouestionable Enable register. Syntax: STATus:QUEStionable:ENABle <enable> Query Syntax: STATus:QUEStionable:ENABle? Parameter: <enable> (0 ~ 32767) Return parameter: <NR1> Example: STAT:QUES:ENAB 4099 ●The selected bits are then reported to the Status Byte. An enable register defines which bits in the event register will be reported to the Status Byte register group.
Page 306
DAQ-9600 Series User Manual SYSTem Related Commands SYSTem:ALARm? Reads the alarm data from the alarm queue. A record of up to 20 alarms can be stored in the instrument's alarm queues. Return parameter: <info> Example: SYST:ALAR? Returns: +1.12379111E-03 VDC,2021,01,28,00,43,39.218,101,0,1 +1.12379111E-03 VDC,2021,01,28,00,43,39.218,101,0,1 4 5 6 1.
Page 307
REMOTE CONTROL SYSTem:BEEPer:ERRor Enables (On) or disables (Off) the beeper to sound on an SCPI error. Syntax: SYSTem:BEEPer:ERRor {OFF|ON} Query Syntax: SYSTem:BEEPer:ERRor? Parameter: 0 | 1 | OFF | ON Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: SYST:BEEP:ERR ON SYSTem:BEEPer:STATe...
Page 308
DAQ-9600 Series User Manual SYSTem:CPON Resets the module in the specified slot to its power-on state (CPON means "card power on"). This opens all channels on the module. Syntax: SYSTem:CPON {<slot>|ALL} Parameter: <slot> (1 | 2 | 3) | ALL...
Page 309
REMOTE CONTROL SYSTem:LOCal Enables local control (front panel control) and disables remote control. SYSTem:REMote Enables remote control and disables local control (front panel control, all key are disable besides Shift key(return to local control)). SYSTem:PARameter:LOAD Load the system parameters from 0 of 3 memory locations. Syntax: SYSTem:PARameter:LOAD <mem_num>...
Page 310
DAQ-9600 Series User Manual SYSTem:PERSona[:MANufacturer]:DEFault Sets or returns the default manufacturer's ID string. Syntax: SYSTem:PERSona[:MANufacturer]:DEFault Query Syntax: SYSTem:PERSona[:MANufacturer]:DEFault? Parameter: [None] Return parameter: "<string>" Example: SYST:PERS:DEF? Returns: "Keysight Technologies" SYSTem:PERSona:MODel Sets the instrument's model number for backward compatibility. Syntax: SYSTem:PERSona:MODel "<string>"...
Page 311
REMOTE CONTROL SYSTem:RELay:CYCLes? Reads the cycle count on the specified channels. In addition to the channel relays, you can also query the count on the Analog Bus relays and module relays. Query Syntax: SYSTem:RELay:CYCLes? (@<ch_list>) Return parameter: <NR1> Example: SYST:REL:CYCL? (@101) Returns: +100 SYSTem:RELay:CYCLes:CLEar Resets the cycle count on the specified channels.
Page 312
DAQ-9600 Series User Manual SYSTem:SCPi:MODE Sets or returns the SCPI mode. The SCPI mode is used to determine whether the *IDN? query returns the "NORmal" or "COMPatible" identification string. See the SYSTem:IDNStr command for details. Syntax: SYSTem:SCPi:MODE {NORmal|COMPatible} Query Syntax: SYSTem:SCPi:MODE?
Page 313
REMOTE CONTROL SYSTem:SLOT:LABel Allows you to add a custom label to the module in the specified slot. Syntax: SYSTem:SLOT:LABel <slot>,"<string>" Query Syntax: SYSTem:SLOT:LABel? <slot> Parameter: <slot> (1 | 2 | 3); "<string>", max length 10 characters. Return parameter: "<string>" Example: SYST:SLOT:LAB 1,"...
Page 314
DAQ-9600 Series User Manual SYSTem:UPTime? Returns the amount of time that the instrument has been running since the last power-on. Return parameter: <time> (dd,hh,mm,ss) Example: SYST:UPT? Returns: +0,+1,+25,+53 ●Typically used to verify that the instrument is warmed up sufficiently before calibration.
Page 315
REMOTE CONTROL SYSTem COMMunication Commands SYSTem:COMMunicate:GPIB:ADDRess Sets or returns the GPIB address that is only on GPIB communication bus. Syntax: SYSTem:COMMunicate:GPIB:ADDRess <address> Query Syntax: SYSTem:COMMunicate:GPIB:ADDRess? Parameter: <address> (0 ~ 30) Return parameter: <NR1> Example: SYST:COMM:GPIB:ADDR 15 SYSTem:COMMunicate:LAN:DHCP Enables (On) or disables (Off) the use of the Dynamic Host Configuration Protocol (DHCP) for the instrument.
Page 316
DAQ-9600 Series User Manual SYSTem:COMMunicate:LAN:DOMain? Returns the current network domain name. Return parameter: "<name>" Example: SYST:COMM:LAN:DOM? Returns: "abc.com" ●If a domain name has not been assigned, a null string ( " " ) is returned. SYSTem:COMMunicate:LAN:GATeway Sets or returns the Gateway address.
Page 317
REMOTE CONTROL SYSTem:COMMunicate:LAN:IPADdress Sets or returns the IP address. Syntax: SYSTem:COMMunicate:LAN:IPADdress "<address>" Query Syntax: SYSTem:COMMunicate:LAN:IPADdress? {CURRent|STATic} Parameter: "<address>" Return parameter: "xxx.xxx.xxx.xxx" CURRent : Returns address currently being used by the instrument. STATic : Returns static address from non-volatile memory. This address is used if DHCP is disabled or unavailable.
Page 318
DAQ-9600 Series User Manual SYSTem:COMMunicate:LAN:TCP:ENABle Enables (On) or disables (Off) the use of the Transmission Control Protocol (TCP) for the instrument. Syntax: SYSTem:COMMunicate:LAN:TCP:ENABle {OFF|ON} Query Syntax: SYSTem:COMMunicate:LAN:TCP:ENABle? Parameter: 0 | 1 | ON | OFF Return parameter: 0 | 1, (0 = OFF, 1 = ON)
Page 319
REMOTE CONTROL SYSTem:COMMunicate:LAN:TELNet:ENABle Enables (On) or disables (Off) the use of the Telecommunications Network (TELNET) for the instrument. Syntax: SYSTem:COMMunicate:LAN:TELNet:ENABle {OFF|ON} Query Syntax: SYSTem:COMMunicate:LAN:TELNet:ENABle? Parameter: 0 | 1 | ON | OFF Return parameter: 0 | 1, (0 = OFF, 1 = ON) Example: SYST:COMM:LAN:TELN:ENAB ON SYSTem:COMMunicate:LAN:TELNet:TIMeout...
Page 320
DAQ-9600 Series User Manual SYSTem:COMMunicate:LAN:TELNet:PROMpt Sets or returns the telnet prompt message. Syntax: SYSTem:COMMunicate:LAN:TELNet:PROMpt "<string>" Query Syntax: SYSTem:COMMunicate:LAN:TELNet:PROMpt? Parameter: "<string>", max length 15 characters Return parameter: "<string>" Example: SYST:COMM:LAN:TELN:PROM "DAQ9600>" SYST:COMM:LAN:TELN:PROM? Returns: DAQ9600> SYSTem:COMMunicate:LAN:TELNet:WMESsage Sets or returns the telnet welcome message that telnet communication connect success.
Page 321
REMOTE CONTROL SYSTem:COMMunicate:LAN:UPDate Stores any changes made to the LAN settings into non-volatile memory and restarts the LAN driver with the updated settings. Parameter: [None] Example: SYST:COMM:LAN:UPD ●This command must be sent after changing the settings for DHCP, DNS, gateway, hostname, IP address, subnet, mask, or WINS. SYSTem:COMMunicate:LAN:WEB:ENABle Enables (On) or disables (Off) the use of the WEB page for the instrument.
Page 322
DAQ-9600 Series User Manual TRIGger Commands TRIGger:COUNt Sets or returns the number of trigger counts. Syntax: TRIGger:COUNt {<count>|MIN|MAX|DEF|INFinity} Query Syntax: TRIGger:COUNt? [{MIN|MAX|DEF}] Parameter: <count> (1 ~ 1,000,000); DEF: 1 Return parameter: <NRf> Example: CONF:VOLT:DC 10(@101,103) ROUT:SCAN (@101,103) TRIG:COUN 2 READ? ●For a continuous trigger (INFinity), the query returns "+9.90000000E+37".
Page 323
REMOTE CONTROL TRIGger:SOURce Selects or returns current trigger source. Syntax: TRIGger:SOURce <source> Query Syntax: TRIGger:SOURce? Parameter: <source> (IMMediate | EXTernal | BUS | TIMer | ALARm{(1|2|3|4)}) Return parameter: IMM | EXT | BUS | TIM | ALAR{(1|2|3|4)} IMMediate = Continuous scan trigger EXTernal = An external TTL-compatible pulse trigger BUS = Software trigger TIMer = Internally paced timer trigger...
Page 324
DAQ-9600 Series User Manual TRIGger:TIMer Sets the trigger-to-trigger interval (in seconds) for measurements on the channels in the present scan list. Syntax: TRIGger:TIMer {<seconds>|MIN|MAX|DEF} Query Syntax: TRIGger:TIMer? [{MIN|MAX|DEF}] Parameter: <second> (0 ~ 360,000s); DEF: 10 Return parameter: <NR1> Example: TRIG:SOUR TIM TRIG:TIM: 3600 ●This command defines the time from the start of one trigger to the start of...
Page 325
REMOTE CONTROL IEEE 488.2 Common Commands *CLS Clears the Event Status register (Output Queue, Operation Event Status, Questionable Event Status, Standard Event Status Register) *ESE Sets or returns the ESER (Event Status Enable Register) contents. Syntax: *ESE <enable> Query Syntax: *ESE? Parameter: <enable>...
Page 326
DAQ-9600 Series User Manual *IDN? Returns the manufacturer, model No., serial number and system version number. Example: *IDN? Returns: GWInstek,DAQ-9600,000000000,M0.93_S0.86 *OPC Sets operation complete bit (bit0) in SERS (Standard Event Status Register) when all pending operations are completed. Returns 1 to the output buffer after all pending commands complete. Other commands cannot be executed until this command completes.
Page 327
REMOTE CONTROL *PSC Clears or returns the Power On status. Syntax: *PSC {0|1} Query Syntax: *PSC? Parameter: 0 | 1 Return parameter: 0 | 1; (0= disables, 1= enables) ●Enables (1) or disables (0) the clearing of certain enable registers at power Questionable Data Register (STATus:OPERation:ENABle) Standard Operation Register (STATus:QUEStionable:ENABle) Alarm Register (STATus:ALARm:ENABle)
Page 328
DAQ-9600 Series User Manual *SAV Save the system parameters to 1 of 3 memory locations. Syntax: *SAV <mem_num> Parameter: <mem_num> (1 ~ 3) Example: *SAV 2 *SRE Sets or returns the SRER (Service Request Enable Register) contents. Syntax: *SRE <enable>...
Page 329
REMOTE CONTROL *TRG Manually triggers the DAQ-9600 if TRIG:SOUR is selected to BUS. Example: TRIG:SOUR BUS INIT *TRG FETC? *TST? Runs a standard self-test which is invoked at power-on. It will take few seconds to complete. Return parameter: 0 | 1; (0 = pass, 1 = one or more tests failed)
DAQ-9600 Series User Manual Status system The diagram below is a description of the status system Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com...
Page 331
REMOTE CONTROL NOTE:The overload bits are set once per INITiate command. If you clear an overload bit, it is not set again until a new INITiate is sent. The following table lists the bit definitions for the Questionable Data Register: Name Decimal Definition...
Page 332
DAQ-9600 Series User Manual Not Used (Reserved for future use) Scanning The instrument is scanning. Waitig For Instrument is waiting for a trigger. Trigger Not Used (Reserved for future use) USB MSD A USB mass storage device (USB drive) has been detected detected.
Page 333
REMOTE CONTROL Alarm 4 Alarm 4 is triggered. Not Used 1024 (Reserved for future use) Not Used 2048 (Reserved for future use). Lower Limit 4096 A lower limit alarm has occurred. Upper Limit 8192 An upper limit alarm has occurred. Not Used 16384 (Reserved for future use)
Page 334
DAQ-9600 Series User Manual e Data Register (bits must be enabled, see STAT:QUES:ENAB). Message Data is available in the instrument's output buffer. Available Standard One or more bits are set in the Standard Event Register Event (bits must be enabled, see *ESE).
DAQ-9600 Series User Manual Fuse Replacement 1. Unplug power cord and place Steps dual flat-blade drivers into the grooves of fuse socket sideways followed by pinching together to pull out the fuse socket. 2. The fuse socket appears. The “240” symbol within the hole on fuse socket indicates the line voltage is positioned as 240V.
APPENDIX Battery Replacement This chapter describes the procedure of battery replacement in Beforehand the front panel. Before start, it is required to let a certified and trained technician properly aware of potential risks to disassemble instrument case. Some of the electrical connections are dynamic and even available after powering off the instrument.
Page 338
DAQ-9600 Series User Manual 5. Use fingers to take the battery out off the compartment with ease. 6. Dispose or recycle the used battery in accord with the applicable local regulations. 7. Place a new battery (CR2032) into the compartment and beware of the polarity (+, -).
APPENDIX Factory Default Parameters Channel Parameter Factory Default Item List Save/Load for Parameter Group 1 - 3 Slot1 None Slot2 None Slot3 None Measure Switch JoinBank Interval Parameter Factory Default Item List Save/Load for Parameter Group 1 - 3 TrigSource Auto Sweep Sweeps INF...
Page 340
DAQ-9600 Series User Manual Menu Parameter Factory Default Item List Save/Load for Parameter Group 1 - 5 Beep Key Sound System Time Sync Open Brightness AutoOff AutoOff Time 30min 1ST Font Color White Display Math Font Color White Math Off Display Mode Off...
APPENDIX Specifications General This section lists the general characteristics of the instrument. All specifications are ensured only under a single display. At least 1 hour of warm-up time is required before applying these specifications. Note MAX measuring voltage DC600V, AC400V. ...
DAQ-9600 Series User Manual DAQ-9600 Section DC Characteristics DC Voltage 24 Hour 90 Day 1 Year Temperature Range TCAL ± 1 ˚C TCAL ± 5 ˚C TCAL ± 5 ˚C Coefficient/˚C 100.0000 mV 0.0030 + 0.0050 0.0040 + 0.0060 0.0050 + 0.0060 0.0005 + 0.0005...
Page 343
APPENDIX Diode Test 24 Hour 90 Day 1 Year Temperature Range TCAL ± 1 ˚C TCAL ± 5 ˚C TCAL ± 5 ˚C Coefficient/˚C 0.002 + 0.030 0.008 + 0.030 0.01 + 0.03 0.001 + 0.002 Accuracy Specifications: ± ( % of reading + % of range ) Tél.
Page 344
DAQ-9600 Series User Manual Measuring Characteristics DC Voltage Input Resistance Range 100 mV 10 MΩ or Auto(>10 GΩ) Selectable 10 V 100 V 10 MΩ±1% 600 V Input Bias <30 pA (Typ, 25°C) Input Protection 600 V on all ranges...
Page 345
APPENDIX in 2-wire ohms function. The 100M and 1G ohm ranges are 2-wire only. [4]. This specification applies to the voltage measured from input terminal. 1 mA test current is the typical value. The change of current source leads to the variation in buck of diode junction. Tél.
DAQ-9600 Series User Manual AC Characteristics [2] [3] [4] True RMS AC Voltage 24 Hour 90 Day 1 Year Temperature Range Frequency TCAL ± 1 ˚C TCAL ± 5 ˚C TCAL ± 5 ˚C Coefficient/˚C 100 mV 1.00 + 0.03 1.00 + 0.04...
Page 348
DAQ-9600 Series User Manual Measuring Characteristics True RMS AC Measurement AC-coupled True RMS – measures the ac Voltage Method: component of input with up to 400 Vdc of bias on any range. Crest Factor Maximum 5:1 at full scale Speed...
Page 349
APPENDIX Operating Characteristics Function Speed Digits AC Bandwidth 1/s (>3 Hz) 6 ½ 3 Hz – 300 kHz 5/s (>20 Hz) 5 ½ 20 Hz – 300 kHz 20/s (>200 Hz) 4 ½ 200 Hz – 300 kHz 1/s (>3 Hz) 6 ½...
DAQ-9600 Series User Manual Frequency and Period Characteristics [1] [2] Frequency Period 24 Hour 90 Day 1 Year Temperature Range Frequency TCAL ± 1 ˚C TCAL ± 5 ˚C TCAL ± 5 ˚C Coefficient/˚C 100 mV ~ 3 Hz – 5 Hz 0.100...
APPENDIX Operating Characteristics Function Gate Time Digits 1 s, 100 ms 6 ½ Frequency, Period 10 ms 5 ½ 1 ms 4 ½ [1]. This specification will be available after 60 minutes of warm-up and sine wave input, unless stated otherwise. This specification applies to 1s gate time.
DAQ-9600 Series User Manual Thermistor: (2.2 kΩ, 5 kΩ, 10 kΩ or User Type) 90 Day/1 Year Temperature Range Resolution (23 °C±5 °C)* Coefficient / °C –80 ° to 150 °C 0.001 °C 0.1 °C 0.003 °C/ °C Speed Digits 5 /s,20 /s,60 /s,100 /s...
DAQ-9600 Series User Manual Dimensions – DAQ-9600 All dimensions are shown in millimeters. Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com 127 rue de Buzenval BP 26 - 92380 Garches...
INDEX Dimensions – Module All dimensions are shown in millimeters. Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com 127 rue de Buzenval BP 26 - 92380 Garches...
DAQ-9600 Series User Manual Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. declare that the CE marking mentioned product satisfies all the technical relations application to the product within the scope of council: Directive: EMC; LVD; WEEE; RoHS The product is in conformity with the following standards or other normative documents: ◎...
Page 358
DAQ-9600 Series User Manual Triggering ............50 overview ..........206 Web control Web control interface ........206 Tél. 01 47 95 99 45 e-mail : tem@es-france.com ES France - Département Tests & Mesures Fax. 01 47 01 16 22 Site Web : www.es-france.com...