GW Instek DAQ-9600 Quick Start Manual
Hide thumbs Also See for DAQ-9600:

Advertisement

QUICK START
GUIDE
DAQ-9600
EN
ISO-9001 CERTIFIED MANUFACTURER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DAQ-9600 and is the answer not in the manual?

Questions and answers

Summary of Contents for GW Instek DAQ-9600

  • Page 1 QUICK START GUIDE DAQ-9600 ISO-9001 CERTIFIED MANUFACTURER...
  • Page 2 This Quick Start Guide contains proprietary information, which is protected by copyright. All rights are reserved. No part of this Quick Start Guide may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this Quick Start Guide was correct at the time of printing.
  • Page 3: Afety Instructions

    AFETY INSTRUCTIONS Safety Symbols These safety symbols may appear in the user manual or on the instrument. Warning: Identifies conditions or practices that could result Warning in injury or loss of life. Caution: Identifies conditions or practices that could result Caution in damage to the instrument or to other properties.
  • Page 4: Etting Started

    ETTING STARTED Main Features Performance • The highest DCV accuracy: 35ppm • The highest current:2A • The highest voltage: 600VDC,400VAC • The highest ACV frequency response: 300 kHz • The fastest sampling rate: 38.4K Readings /sec • Internal memory:100k read memory •...
  • Page 5: Front Panel Overview

    Appearance Front Panel Overview Home Data Acquisition System Monitor Scan : Long Push Enter Channel Interval Edit Alarm View Module Average Math Auto ON / STBY Menu Lock Local Description 1. USB host prot 2. Power switch 3. Main display 4.
  • Page 6: Rear Panel Overview

    Rear Panel Overview LINE RATING Mini GPIB 50/60Hz 50VA MAX. FUSE LINE 100V 250V 120V T0.125A 220V 240V Disconnect power cord and test leads before replacing fuse. For continued fire protection , use specified line fuse. Digital I/O WARNING To avoid shock , remove inputs before opening.
  • Page 7 TART UP Power Up 1. Ensure the correct line voltage is clearly shown on the fuse socket (240V in the right figure for example). 2. Connect the power cord to the AC Voltage input. Make sure the ground connector on the power cord is connected to a safety ground.
  • Page 8 Set Up Home Data Acquisition System Monitor Scan : Long Push Enter Channel Interval Edit Alarm View Module Math Average Auto ON / STBY Menu Lock Local Pull out the handle sideways and rotate clockwise for the applications below. Tilt Horizontal Place the unit horizontally.
  • Page 9 ODULE OVERVIEW Modules List The DAQ-9600 is available for a series of plug-in modules to Backgroud provide user with measurements, switching as well as control capabilities. Each module owns specific microprocessor, which efficiently shares loading from the processor of mainframe and thus lessens, in order to faster throughput, backplane communications.
  • Page 10 Module Slot Cover Removing Background Prior to module installation, follow the steps below for how to remove a module slot cover from DAQ-9600 unit. Steps First release inner hook by pressing on curve area from either right or left side on slot cover.
  • Page 11: Module Installation

    Module Installation Background Follow the steps below for how to connect wire to a module and install it to a slot from the rear panel of DAQ-9600 unit. Steps Use a Phillips-head screwdriver to loose the screw from the top of a module followed by taking away the upper cover from module.
  • Page 12 DAQ-9600 unit. To install/uninstall the modules from the slots of rear panel in the midst of Note power on will reboot the DAQ-9600 unit. Modules Introduction Background This subchapter introduces each plug-in module with block diagram and schematics available for DAQ-9600 unit.
  • Page 13 DAQ-900 20-Channel Solid-State Multiplexer Background Partitioned into 2 banks and each bank consists of 10 two- wire channels, this module has up to 20 channels, which switch both Hi and Lo inputs, and it offers fully isolated inputs to an external device or to the internal DMM.
  • Page 14 DAQ-903 40-Channel Single-Ended Multiplexer Background This module is partitioned into 2 banks and each bank consists of 20 channels. The all 40 channels, with a common Lo for the module, switch Hi only. This module is suitable for applications of high-density switching which are in demand of, with a common Lo, single-wire inputs.
  • Page 15 DAQ-909 8-Channel High Voltage Multiplexer Background Partitioned into 2 banks and each bank consists of 4 two- wire channels, this module has two additional fused channels to make direct and calibrated AC or DC current measurement with internal DMM. The 10 channels in total, which switch both Hi and Lo inputs, offer fully isolated inputs to an external device or to the internal DMM.
  • Page 16 DAQ-907 Multifunction Module Background The DAQ-907 multifunction module, which consists of up to 7 available channels, expands the capabilities of DAQ system by providing majorly three functions described below in a neatly single module, making it ideal for automated testing and versatile signal measurements. ▪...
  • Page 17 PECIFICATIONS General • All specifications are ensured only under a single display. • At least 1 hour of warm-up time is required before Note applying these specifications. • MAX measuring voltage DC600V, AC400V. • Power Supply: 100 / 120 / 220 / 240 VAC ±10% •...
  • Page 18 Internal DMM measurement functions supported DAQ- DAQ-900 DAQ-901 DAQ-903 DAQ-909 904/908/-907 √ √ √ √ AC/DC Voltage √ √ AC/DC Current √ √ √ √ Freq./Period √ √ √ √ 2Wire Resistance √ √ √ 4Wire Resistance √ √ √ Thermocouple √...
  • Page 19: Eclaration Of Conformity

    eclaration of Conformity GOOD WILL INSTRUMENT CO., LTD. declare that the below mentioned product satisfies all the technical relations application to the product within the scope of council: Directive: EMC; LVD; WEEE; RoHS The product is in conformity with the following standards or other normative documents ◎...