Installing A Valve Kit; Pressure Relief Valve; Programming Domestic Hot Water Preheat - Rinnai E75CRN Installation & Servicing Instructions Manual

High efficiency condensing gas boiler
Table of Contents

Advertisement

Available languages

Available languages

6.5.5

Installing a valve kit

6.5.6

Pressure relief Valve

6.5.7

Programming domestic hot water preheat

i
NOTICE
A means to isolate the domestic plate heat exchanger for cleaning must be provide
at installation. Refer to figure 10 for proper piping layout. A Rinnai valve kit can be
used on domestic water pipes for all combi boilers to allow for cleaning of the plate
heat exchanger and installation the domestic hot water pressure relief valve.
Rinnai recommends the use of a plumbing installation kit when connecting the
domestic water lines to the boiler.
• Use of this kit will assist in flushing the flat plate heat exchanger in areas where
water quality issues exist, as well as improve overall product serviceability.
-
An approved pressure relief valve is required by Rinnai for all water heating
systems.
-
The relief valve must comply with the standard for Relief Valves and Automatic Gas
Shutoff Devices for Hot Water Supply Systems ANSI Z21.22 and/or the standard
Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum
Relief Valves, CAN1-4.4.
-
The relief valve must be rated up to 150 psi and to at least the maximum BTU/hr
of the appliance.
-
The discharge from the pressure relief valve should be piped to the ground or into
a drain system to prevent exposure or possible burn hazards to humans or other
plant or animal life. Follow local codes. Water discharged from the relief valve
could cause severe burns instantly, scalds, or death.
-
The pressure relief valve must be manually operated once a year to check for
correct operation.
-
The relief valve should be added to the hot water outlet line according to the
manufacturer instructions. DO NOT place any other type valve or shut off device
between the relief valve and the combi boiler.
- Do not plug the relief valve and do not install any reducing fittings or other
restrictions in the relief line. The relief line should allow for complete drainage of
the valve and the line.
-
If a relief valve discharges periodically, this may be due to thermal expansion in a
closed water supply system. Contact the water supplier or local plumbing inspector
on how to correct this situation. Do not plug the relief valve.
-
Rinnai does not require a combination temperature and pressure relief valve for
this appliance. However local codes may require a combination temperature and
pressure relief valve.
-
If a combi boiler is installed in a closed water supply system, such as one having
a backflow preventer in the cold water supply line, means shall be provided to
control thermal expansion. Contact the water supplier or local plumbing inspector
on how to control thermal expansion.
When plate warming is selected the brazed plate heat exchanger is kept warm and
this reduces the wait time for domestic hot water by approximately 1 minute. When
this setting is turned off the wait time for DHW is increased by approximately 1 minute.
E50CRN Only: Plate warming can only be deactivated when the flow switch
accessory (part number 803000015) has been installed. If no flow switch is
installed and parameter 36 is altered from the factory setting no DHW production
will be possible.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

E50crnE75crpE110crnE110crp

Table of Contents