CONTENTS 1 Description ..............................1.1 Models ............................... 1.2 Tank Protection ..........................1.3 Thermal Insulation ..........................1.4 Connection points on the tank ......................1.5 Packaging ............................2 General Information ............................3 Dimensions and Other Technical Data ......................4 Operation ............................... 5 Typical Layout Examples with Thermal Store .................... 6 Installation and Commissioning ........................
1 - Description PS N+ Thermal Stores are intended for storing and subsequent distribution of thermal energy from solid-fuel fired boilers, heat pumps, solar collectors, electric boilers etc. These tanks do not enable installation of heat exchangers, only direct installation of an electric heating element. 230V or 3x230V/400V heating elements (2-12 kW output) can be installed directly into the 6/4”...
3 - Dimensions and Other Technical Data Dimensions scheme ØD1 CONNECTIONS pos. conn. ØD Heat sources G 6/4" F G 6/4" F Heating system G 6/4" F G 6/4" F Control and safety G 1/2" F G 1/2" F G 1/2" F G 1/2"...
4 - Operation In a thermal store, heating water can be heated up by various types of hot-water boilers, renewable energy sources (heat pumps, solar collectors), or possibly also by electric heating elements. The thermal store is connected to the energy source using a G 6/4“ connection fitting. Should the tank be connected to a solar thermal system, a heat exchanger shall be used for the connection because heating water is not used as the heat transfer fluid in a solar thermal system.
Page 6
Example II. Biomass boiler (fireplace insert/stove) and electric heating element. │...
6 - Installation and Commissioning Installation shall meet valid rules and may be done by qualified staff only. Defects caused by improper installation, use or handling are not covered by warranty. After the tank is installed and connected to an existing heating system, it is recommended to clean the entire heatingsystem using a suitable cleaning agent, e.g.
7 - Installing Insulation on the Tank Product description Fleece insulation with a hard polystyrene surface, closed by a quick lock. Warning Insulation installation shall be done in two or three persons, depending on its size. The PU leather surface coated fleece insulation must not be installed at temperatures below 20 °C.
8 - Maintenance If the tank is fitted with a heating element, disconnect it from the mains first. Clean the exterior of the tank with a soft cloth and a mild detergent. Never use abrasive cleaners or solvents. Check all tank connections for leaks. 9 - Disposal Packaging shall be disposed of in compliance with the valid rules.
Need help?
Do you have a question about the PS 200 N+ and is the answer not in the manual?
Questions and answers