Pulsar PSU-B-13,8V/S-3,5A/1/EL-TR-17Ah/MC Quick Start Manual

Pulsar PSU-B-13,8V/S-3,5A/1/EL-TR-17Ah/MC Quick Start Manual

Buffer, switching power supply unit

Advertisement

Quick Links

PSU-B-13,8V/S-3,5A/1/EL-TR-17Ah/MC
PSBC 3512
v.1.2
Buffer, switching power supply unit
EN
th
Edition: 3 from the 24
June 2010
th
Supercedes edition: 2 from the 16
December 2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSU-B-13,8V/S-3,5A/1/EL-TR-17Ah/MC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pulsar PSU-B-13,8V/S-3,5A/1/EL-TR-17Ah/MC

  • Page 1 PSU-B-13,8V/S-3,5A/1/EL-TR-17Ah/MC PSBC 3512 v.1.2 Buffer, switching power supply unit Edition: 3 from the 24 June 2010 Supercedes edition: 2 from the 16 December 2008...
  • Page 2: Table Of Contents

    Features of the power supply unit: 13.8 VDC uninterruptible power supply AW output of power supply unit failure, tripped • • Controlling of the battery charging and • maintaining short-circuit (SCP) • Protecting the battery against excessive overload (OLP) • •...
  • Page 3: Block Diagram

    1.2. Block diagram (fig.1). Fig.1. Block diagram of the power-supply unit.
  • Page 4 1.3. Description of elements and connection links of the power-supply unit (tab.1, tab.2, fig.2). Table 1. Element no. Description [Fig. 2] F1 fuse in the battery circuit START pushbutton (power activation without AC supply) JP-B, jumper - configuration of UVP battery protection function JP-B= protection function (disconnection) of the battery off •...
  • Page 5 Fig.2. The view of the power-supply.
  • Page 6: Technical Parameters

    1.4. Technical parameters: - electrical parameters (tab.3) - mechanical parameters (tab.4) - operation safety (tab.5) - operation parameters (tab.6) (tab. 3). lectrical parameters Supply voltage 230V/AC (-15%/+10%) Supply frequency 50Hz PSU power P 49 W Current consumption from the transformer 0.39 A (5.0 A „cold boot”) Output voltage 11.0 V÷...
  • Page 7: Installation

    Operation safety (tab.5). Protection class PN-EN 60950-1:2004 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Electrical strength of insulation: - between input (network) circuit and output circuits of power-supply (I/P- 3000 V/AC min. O/P) - between input circuit and PE protection circuit (I/P-FG) 1500 V/AC min.
  • Page 8: Technical Output

    - TAMPER signalization of power-supply unit opening 6. Set appropriate battery charging current - jumper ‘J1’ (refer to table 1 and figure 2). 7. Using the dip switch ‘JP-B’ determine whether the function of disconnecting the discharged battery U<10V (+/- 5%) is to be on or off.
  • Page 9: Overloads Or Short Circuits To The Psu

    4. Handling and operation. 4.1 Overloads or short circuits to the PSU. The AUX output of the PSU is equipped with the PTC polymer fuse assisted protection. If the load of the exceeds I (load 110% ÷ 150% @25ºC of the PSU power), the output voltage is automatically disconnected and this is indicated by the green diode going off.
  • Page 10 GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (manufacturer) grants a two-year quality warranty for the equipment, starting from the date of purchase placed on the purchase order.