Fault
" Please empty con-
densate container"
and programme ter-
minated.
Condensation in the
condensation tank
even though the water
drain hose is connec-
ted.
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
The drying time is too
long.
Cause and troubleshooting
Water drain hose is blocked.
Rinse the water drain hose with tap water.
The filter for the condensation tank is soiled.
→ "Clean the filter for the condensation tank.",
Page 54.
Foreign object is located in the base unit
→ "Opening the base unit", Page 51.
1.
Remove the foreign objects that are present.
2.
→ "Closing the base unit", Page 52.
3.
Dirt in the appliance.
Run the intensive appliance care programme.
→ "Appliance care", Page 48
The appliance uses condensation for the automatic
self-cleaning.
Not a fault – no action required.
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 39
Start/Reload has not been pressed.
Press Start/Reload .
No programme set.
→ "Setting a programme", Page 35.
1.
→ "Starting the programme", Page 36.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
Condensation pump active.
Not a fault – normal operating noise.
Compressor ventilation active.
Not a fault – normal operating noise.
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 36
The ambient temperature is greater than 30 °C.
Ensure that the appliance is only operated in a well
ventilated location.
The ambient temperature is lower than 15 °C.
Troubleshooting en