Carrier 30KAV-ZE Series Installation, Operation And Maintenance Instructions page 63

Liquid chiller with variable speed screw compressor and greenspeed smart technology
Table of Contents

Advertisement

12 - OPTIONS
Option
No.
Service valve set
92
Compressor discharge
93A
valves
21 bar evaporator
104
LP VSD dual-pump
116A
hydraulic mod.
HP VSD dual-pump
116W
hydraulic mod.
High Energy Efficiency
119
High Energy
119+
Efficiency+
148D Bi-directional communication board
Lon gateway
Bacnet over IP
149
Modbus over IP and
149B
RS485
Energy Management
156
Module
Input contact for
Refrigerant leak
159
detection
Dual relief valves on
194 Three-way valve upstream of dual relief
3-way valve
Compliance with Swiss
197
regulations
Compliance with
199 EAC certification
Russian regulations
Compliance with
200 Unit approved to Australian code
Australian regulations
Insulation of the evap.
256
in/out ref.lines
Enviro-Shield anti-
262
corrosion protection
Super Enviro-Shield
anti-corrosion
263
protection
Description
Liquid line valve (evaporator inlet) and
compressor suction line valve
Shut-off valve on the compressor 
discharge piping
Reinforced evaporator for extension of the
maximum water-side service pressure to
21 bar (standard 10 bar)
Dual low-pressure water pump with
variable speed drive (VSD), pressure
transducers. Multiple possibilities of water
flow control.  For more details, refer to the 
dedicated chapter.
Dual high-pressure water pump with
variable speed drive (VSD), pressure
transducers. Multiple possibilities of water
flow control (expansion tank with built-in 
safety hydraulic components available in
option)
Additional condenser coil to improve unit
energy efficiency
Additional condenser coil plus EC fans to
improve unit energy efficiency
complying with Lon Talk protocol
Bi-directional high-speed communication
using BACnet protocol over Ethernet
network (IP)
Bi-directional high-speed communication
using Modbus protocol over Ethernet
network (IP)
EMM Control board with additional inputs/
outputs. See Energy Management Module
option chapter
0-10 V signal to report any refrigerant
leakage in the unit directly on the
controller (the leak detector itself must be
supplied by the customer)
valves on the shell and tubes evaporator
Additional tests on the water heat
exchangers: Supply (additional of PED
documents) supplementary certificates 
and test certifications
Thermal insulation of the evaporator
entering/leaving refrigerant lines with
flexible, UV resistant insulation
Coating by conversion process which
modifies the surface of the aluminum 
producing a coating that is integral to the
coil. Complete immersion in a bath to
ensure 100% coverage. No heat transfer 
variation, tested 4000 hours salt spray per
ASTM B117
Extremely durable and flexible epoxy 
polymer coating applied on micro channel
heat exchangers by electro coating
process, final UV protective topcoat. 
Minimal heat transfer variation, tested
6000 hours constant neutral salt spray per
ASTM B117, superior impact resistance
per ASTM D2794
Advantage
Allow isolation of various refrigerant
circuit components for simplified 
service and maintenance
Simplified maintenance
Covers applications with a high
water column on the condenser side
(typically high buildings)
Easy and fast installation (plug &
play), significant pumping energy 
cost savings (more than two-thirds),
tighter water flow control, improved 
sytem reliability
Easy and fast installation (plug &
play), significant pumping energy 
cost savings (up to two-thirds),
tighter water flow control, improved 
sytem reliability
Enhances the unit energy efficiency 
performance
Enhances the unit energy efficiency 
performance
Connects the unit by communication
bus to a building management
system
Easy and high-speed connection by
ethernet line to a building
management system. Allows access
to multiple unit parameters
Easy and high-speed connection by
ethernet line to a building
management system. Allows access
to multiple unit parameters
Extended remote control capabilities
(Set-point reset, ice storage end,
demand limits, boiler on/off 
command...)
Immediate customer notification of 
refrigerant losses to the atmosphere,
allowing timely corrective actions
Valve replacement and inspection
facilitated without refrigerant loss.
Comforms to European standard
EN378/BGVD4
Conformance with Swiss regulations 0350-1300 0350-0800 0500-1250
Conformance with Russian
regulations
Conformance with Australian
regulations
Prevents condensation on the
evaporator entering/leaving
refrigerant lines
Improved corrosion resistance,
recommended for use in moderately
corrosive environments
Improved corrosion resistance,
recommended for use in extremely
corrosive environments
Use
Use
Use
30KAV-ZE
30KAVPZE
30KAVIZE
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-0600 0350-0600
NO
0350-0600 0350-0600
NO
0350-1100
NO
NO
0350-1100
NO
NO
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
0350-1300 0350-0800 0500-1250
63