Download Print this page

Current - Aktakom AM-1142 User Manual

6600 counts digital multimeter

Advertisement

4.2.10 Current

DCA:
Range
660PA
6600PA
66mA
600mA
10A
ACA:
Range
660PA
6600PA
66mA
600mA
10A
Above accuracies can be guaranteed within 5%~100% of the full range.
The true RMS meter and the true RMS+PEAK meter has residual value within 10 counts when the
test leads are shorten, but that will not affect the accuracy of measurement.
Overload protection: F 10A/1000V fuse for 10A range.
F 0.63A/1000V fuse for PA and mA ranges.
Maximum input current: 600mA dc or 600mA ac rms for PA and mA ranges,
For measurements>7A, 4 minutes maximum ON to measure 10 minutes OFF; Above 10A unspecified.
Resolution
0.1PA
1PA
0.01mA
0.1mA
10mA
Resolution
0.1PA
1PA
0.01mA
0.1mA
10mA
10A dc or 10A ac rms for 10A ranges.
6600 COUNTS DIGITAL MULTIMETER
Accuracy
±(1.0% +3)
±(1.5% +3)
±(1.8% +5)
Accuracy
±(1.5% +5)
±(1.8% +8)
±(2% +8)
USER'S MANUAL
27

Advertisement