3.2.8 Temperature measurement
To avoid electrical shock and/or damage to the instrument, do not apply more than 250Vdc or
220Vac rms between the °C terminal and the COM terminal.
To avoid electrical shock, do not use this instrument when voltages at the measurement surface
exceed 60v dc or 24v rms. Ac.
To avoid damage or burns. Do not make temperature measurement in microwave ovens.
To measure temperature:
1. Set the rotary switch to C
2. Press SELECT key to select
2. Insert 'K' type thermocouples into the COM terminal and
Socket) Takings care to observe the correct polarity.
3. Touch the object with the thermocouple probe for measurement.
4. Read the stable reading from LCD.
3.2.9 PC Link
The meter has serial data output function. It can be connected with PC by USB interface, so the measured data can
be recorded, analyzed, processed and printed by PC. Before use this function, you need install the PC-Link software
and USB driver in your PC.
PC-LINK SOFT OPERATING MANUAL
1. Make sure the two Install USB driver and Install software files in the attached CD successfully installed before
any measurement.
2. After turning on the meter, press the SHIFT key and the SHIFT symbol will appear on LCD. Then press the
RANGE key to enter PC-Link mode, the symbol "PC-LINK" will appear on LCD, and the serial data output function is
active.
¡ £
¡