2.
Basic Functions
Data Protection
The target drives are deactivated and then reactivated during temporary drive protection.
Even though a system status error may be displayed during this period, this phenomenon is on-
ly temporary. The status returns to normal after the diagnosis is complete.
The following phenomenon may occur during temporary drive protection.
The Fault LEDs (amber) on the operation panel and the drive turn on
-
-
An error status is displayed by the ETERNUS Web GUI and the ETERNUS CLI
Error or Warning is displayed as the system status
Error, Warning, or Maintenance is displayed as the system status
Target drives of the Protection (Shield) function only need to be replaced when drive reactiva-
tion fails.
If drive reactivation fails, a drive failure error is notified as an event notification message (such
as SNMP/REMCS). When drive reactivation is successful, an error message is not notified. To
notify this message, use the event notification settings.
To set the Protection (Shield) function for each storage system, use the subsystem parameter
settings. The maintenance operation privilege is required to perform this setting.
After the settings are changed, the ETERNUS DX does not need to be turned off and on again.
Fujitsu Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Design Guide (Basic)
39
Copyright 2023 Fujitsu Limited
P3AM-7642-32ENZ0