9.1 Console Port

I cannot access the switch using the Console Port.
STEPS
1
Check to see if the switch is connected to your computer using the RS-232 cable.
2
Check to see if the communications program is
configured correctly. Set the communication parameter
as stated here.

9.2 Telnet

I cannot telnet into the switch.
STEPS
1
Make sure you are using the right IP address of the switch. Check the IP address of the switch.
2
Ping the switch from your computer.
If you cannot ping the switch, check the IP addresses in the switch and your computer. Make sure that
both IP addresses are in the same subnet.
3
If these steps fail to correct the problem, contact the distributor.

9.3 Web Configurator

I cannot access the Web Configurator
STEPS
1
Make sure you are using the right IP address of the switch. Check the IP address of the switch.
2
Make sure your login name or password is correct if you have changed them. The default login and
password is root.
2
Make sure there is not an SMT or Telnet session running.
3
Ping the switch from your computer.
If you cannot ping the switch, check the IP addresses in the switch and your computer. Make sure that
both IP addresses are in the same subnet.
Troubleshooting

Table 9-1 Troubleshooting Console Port

CORRECTIVE ACTION

Table 9-2 Troubleshooting Telnet

CORRECTIVE ACTION

Table 9-3 Troubleshooting Web Configurator

CORRECTIVE ACTION
EES-1024AF Intelligent Ethernet Switch
Chapter 9
Troubleshooting
Emulation: auto detect
Baud Rate: 9600 bps
No Parity, 8 data bits, 1 stop bit
Flow Control: None