ES-4024A User's Guide

2.2 Mounting the ES-4024A on a Rack

This section lists the rack mounting requirements and precautions and describes the
installation steps.

2.2.1 Rack-mounted Installation Requirements

• Two mounting brackets.
• Eight M3 flat head screws and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Note: Failure to use the proper screws may damage the unit.

2.2.1.1 Precautions

• Make sure the rack will safely support the combined weight of all the equipment it
contains.
• Make sure the position of the ES-4024A does not make the rack unstable or top-heavy.
Take all necessary precautions to anchor the rack securely before installing the unit.

2.2.2 Attaching the Mounting Brackets to the ES-4024A

1 Position a mounting bracket on one side of the ES-4024A, lining up the four screw holes
on the bracket with the screw holes on the side of the ES-4024A.

Figure 7 Attaching the Mounting Brackets

2 Using a #2 Philips screwdriver, install the M3 flat head screws through the mounting
bracket holes into the ES-4024A.
3 Repeat steps
4024A.
4 You may now mount the ES-4024A on a rack. Proceed to the next section.
2.2.3 Mounting the ES-4024A on a Rack
1 Position a mounting bracket (that is already attached to the ES-4024A) on one side of the
rack, lining up the two screw holes on the bracket with the screw holes on the side of the
rack.
38
1
and
2
to install the second mounting bracket on the other side of the ES-
Chapter 2 Hardware Installation and Connection