CONFIGURING SYSTEM

SELECTING THE VOLTAGE FOR
YOUR SPA
Your spa is designed to operate at either 115V 15
amp; 115V 30 amp, or 230V 50 amp circuit.
When the spa is setup for 115V, the heater will
provide approximately 1000 watts of heat only
when the pump is operating in LOW speed and
the thermostat is calling for heat (NOTE: The
heater does not operate when the pump is on
high speed).
When the spa is connected to 115V 30 amp,
the heater will provide approximately 1000
watts of heat when the pump is operating in
LOW or HIGH speed and the thermostat is
calling for heat.
When the spa is connected to 230 volts, the
heater will provide approximately 4000 watts of
heat when the pump is operating in LOW or HIGH
speed and the thermostat is calling for heat.
All electrical connections must be made in
accordance with the wiring information contained
on the electrical control box cover and the NEC.
Field Converted 115V 30 Amp Control Box
White
White
Black
Black
Green
Green
To convert, remove the cord from the terminal
block and replace with White, Black and Green
#10 wires and connect to 30 amp GFCI Subpanel.
IMPORTANT: After powering up the spa (for 5 minutes) on 115V 30 amp or 230V 50 amp field conversions,
a program configuration is required. Press and Hold JETS button for 30 seconds to access the Low Level
(LL) settings on the control panel. Use the +/- button to change the setting from LL1 Factory Default (non
concurrent heat and high speed) to LL2 (concurrent Heater and High Speed pump) configuration. Press the
MODE button within 25 seconds to save the new program setting.
9
ELECTRICAL REQUIREMENTS
For further inquiries, please contact our Customer Service Team
Email: ahsservice@watkinsmfg.com
115 VOLT INSTALLATION
CONNECTED)
Spas come with a factory-installed power supply
GFCI cord and are to be plugged into a grounded
type 115 volt, 15 ampere receptacle. No other
electrical appliance or fixture can be used on this
circuit.
IMPORTANT: Under NO circumstances should
an extension cord be used. Use of an extension
cord will seriously degrade the performance of the
equipment and can create an electrical hazard.
115 VOLT 30A OR 230 VOLT 50A
(PERMANENTLY CONNECTED FIELD
CONVERSION)
A 115 volt, 30 ampere configuration requires a
30 ampere GFCI Subpanel (not included).
A 230 volt, 50 ampere configuration requires a
50 ampere GFCI Subpanel (not included).
Either one of these installation requires a licensed
electrician.
Field Converted 115/230V Control Box
Red
Red
White
White
Black
Black
Green
Green
To convert, remove the cord and brown jumper
wire from the terminal block. Remove other
end of brown wire from connector and remove
from box. Place Red, White, Black and Green
#8 wires onto terminal block and connect other
end to 50 amp GFCI Subpanel.