ELECTRICAL WIRING
DIAGRAM FOR 230V USE
It is recommended that a licensed electrician in-
stall the power to your spa in accordance with the
National Electric Code and/or any local electrical
codes in effect at the time of installation.
From the House
Breaker Box
ELECTRICAL REQUIREMENTS
For further inquiries, please contact our Customer Service Team
Email: ahsservice@watkinsmfg.com
Power supply installation must include a properly
rated GFCI circuit breaker. The circuit must be
dedicated and should not be shared with any other
appliances. The power supply must be hard wired
into the power pack.
230V Wiring Instructions:
4 wires/Minimum 50 amp GFCI Breaker
#8 AWG 75°C Copper Wire Minimum (less
than 100' (30 m) length)
Special Note:
If the GFCI breaker trips immediately after
attempting to turn on, please check the
White Neutral Wire that is connected to the
spa.
White Neutral Wire that is connected
to Spa Neutral goes HERE.
Red
White
Black
Green
To the Spa
Phone: 888-961-7727