Download Print this page

Electrolux 400 LT Installation And Operating Manual page 23

Vertical refrigerators

Advertisement

R R e e f f r r i i g g e e r r a a t t e e d d m m o o d d e e l l s s w w i i t t h h g g l l a a s s s s d d o o o o r r " " 0 0 ℃ ℃ / / + + 1 1 0 0 ℃ ℃ " "
Temp. range. in
compartment
Room temperature
Refrigeration system
Plastic-coated racks mm:
600 x 400
R R e e f f r r i i g g e e r r a a t t e e d d m m o o d d e e l l s s w w i i t t h h g g l l a a s s s s d d o o o o r r " " – – 2 2 ℃ ℃ / / + + 8 8 ℃ ℃ " " ( ( h h i i g g h h
h h u u m m i i d d i i t t y y ) )
Temp. range. in
compartment
Room temperature
Refrigeration system
Plastic-coated racks mm:
600 x 400
F F r r e e e e z z e e r r m m o o d d e e l l s s w w i i t t h h f f u u l l l l y y i i n n s s u u l l a a t t e e d d d d o o o o r r
Temp. range. in
compartment
Room temperature
Evaporating grilles mm: 600
x 400
1
F F
I I N N S S T T A A L L L L A A T T I I O O N N A A N N D D A A S S S S E E M M B B L L Y Y
W W A A R R N N I I N N G G
Refer to " Warning and Safety
Information ".
F F . . 1 1
I I n n t t r r o o d d u u c c t t i i o o n n
To ensure correct operation of the appliance and maintain
safe conditions during use, carefully follow the instructions
given below in this section.
F F . . 2 2
T T h h e e c c u u s s t t o o m m e e r r ' ' s s r r e e s s p p o o n n s s i i b b i i l l i i t t i i e e s s
The tasks and works required of the Customer are:
• provide an earthed power socket of suitable capacity for the
input specified on the dataplate;
• provide a high sensitivity manual-reset differential thermal-
magnetic switch. For information regarding the electrical
connection, refer to Electrical connection ;
• check the flatness of the surface on which the machine is
placed.
F F . . 3 3
M M a a c c h h i i n n e e s s p p a a c c e e l l i i m m i i t t s s
A suitable space must be left around the machine (for
operations, maintenance, etc.). This space must be increased
in case of use and/or transfer of other equipment and/or means
or if exit routes are necessary inside the workplace. Refer to
F.4 Positioning for information regarding distances from any
other machines present in the room (in fact, close proximity
can create problems of condensate forming on the walls of the
appliance), also taking into consideration the space needed for
door opening.
F F . . 4 4
P P o o s s i i t t i i o o n n i i n n g g
Install the appliance in a ventilated place, away from heat
sources such as radiators or air conditioning systems, to allow
correct cooling of the refrigerating unit components.
If the machine is installed in a place where there are corrosive
substances (chlorine, etc.), it is advisable to go over all the
stainless steel surfaces with a rag soaked in paraffin oil to
create a protective film.
1.
Fixed evaporating grilles in steel coated with non-toxic paint.
0 / +10
32
ventilated
no.
4
– 2 / +8
43
ventilated
no.
4
– 24 / – 15
38
no.
4
F F r r e e e e z z e e r r m m o o d d e e l l s s w w i i t t h h g g l l a a s s s s d d o o o o r r
Temp. range. in
compartment
Room temperature
Refrigeration system
Evaporating grilles mm: 600
1
x 400
W W i i n n e e - - l l i i n n e e m m o o d d e e l l s s
Temp. range. in
compartment
Evaporating grilles mm: 600
1
x 400
F F i i s s h h m m o o d d e e l l s s
Temp. range. in
compartment
Room temperature
Refrigeration system
Trays H = 210
Trays H= 200
C C A A U U T T I I O O N N
When positioning to take into account the
following distances:
• at least 500 mm from the top;
• 50 mm from the sides and back.
min.
50
mm
Never cover the condenser, even temporarily, as this can
compromise proper operation of the condenser and therefore
the appliance.
For information regarding the room temperatures in which the
machine must operate, refer to Technical data paragraph.
The machine must be taken to the place of installation and
the packing base removed only when being installed.
Arranging the machine:
• position the machine in the required place;
• adjust the height and levelling with the adjustment feet, also
checking correct door closing
– 22 / – 15
32
static
no.
4
See paragraph I.5
Switching on and tem-
perature adjustment
for Wine-line models
no.
4
– 7 / + 6
38
ventilated
no.
4
no.
1
min. 500 mm
min.
50
mm
23