Indoor Unit Installation
Installation Instructions – Indoor unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to
the label on the product box to make
sure that the model number of the indoor
unit matches the model number of the
outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you
must choose an appropriate location.
The following are standards that will help
you choose an appropriate location for
the unit.
Proper installation locations meet the
following standards:
Good air circulation
Convenient drainage
Noise from the unit will not
disturb other people
Firm and solid—the location
will not vibrate
Strong enough to support the
weight of the unit
A location at least one meter
from all other electrical
devices (e.g., TV, radio,
computer)
DO NOT install unit in the following
locations:
Near any source of heat,
steam, or combustible gas
Near flammable items such as
curtains or clothing
Near any obstacle that might
block air circulation
Near the doorway
In a location subject to direct
sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that
you should leave ample room for a wall
hole (see Drill wall hole for connective
piping step) for the signal cable and
refrigerant piping that connect the indoor
and outdoor units. The default position
for all piping is the right side of the
indoor unit (while facing the unit).
However, the unit can accommodate
piping to both the left and right.