18 SERVICE WORK ON THE ENGINE
142
Main work
–
Remove protection cap
E00917-10
–
Put throttle grip
E00819-11
–
Plug in wake-up connector
diagnostics connector
The combination instrument lighting is activated.
Info
The connector is included as part of the motorcycle's
separate enclosure.
–
Wait for at least five seconds.
–
Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
–
Wait until you can no longer hear the oil pump working.
–
Disconnect the wake-up connector from the diagnostics con-
nector.
E00918-10
–
Check whether air bubbles are visible in the hose
»
If air bubbles are visible:
–
Repeat the entire procedure until air bubbles are no
longer visible.
–
Mount protection cap on the diagnostics connector.
M01515-10
Finishing work
–
Mount the seat. (
1
of the diagnostics connector.
2
into full throttle position and secure.
3
for priming the oil pump to the
4
.
p. 80)
5
.