Electrical Connection Requirements

!
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence
of local codes with the National Electrical Code, ANSI/NFPA 70; or the Canadian Electrical Code, CSA C22.1
!
The electrical line must be installed by a qualified installer and must meet all local codes. Consult your local
building official for code regulations and recommended procedures.
!
The 24VAC transformer may require a circuit protected by a GFCI (see local building codes).
!
Use a transformer to convert 120VAC power to 24VAC power for the appliance. Supply the transformer with
120VAC at approximately 0.9 amps - make sure the circuit and wiring is appropriately sized. The power supply
must be routed through a switch to turn the appliance on and off (see pg. 41). Multiple Travis Industries, Inc.
24-volt appliances may be placed on a single circuit. Each appliance uses 24VAC at approximately 1.6 amps -
Make sure the circuit and wiring is appropriately sized (see diagrams starting on pg. 22.). If multiple
appliances are powered through a single switch the control modules for each of the individual appliances may
be daisy-chained together.

24VAC Transformer

This appliance must be used with a 24VAC switched circuit. The transformer is sold separately.
Travis Industries offers the following transformer:
-- sku# 94800830 (120v input only with 24v, 26v, and 28v output leads). See the instruction sheet
included with the transformer for details.
See the overview to the right. Consult the
instruction sheet that comes with the
transformer for details.
 