Technical Description Of The Burner; Technical Data; Burner Description; Burner Equipment - Riello 744T0K Installation, Use And Maintenance Instructions

Table of Contents

Advertisement

3

Technical description of the burner

3.1

Technical data

Model
Output - Thermal power
(with air at 20 °C)
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
3.2

Burner description

3
9
1
Pump
2
Control box
3
Reset button with lock-out lamp
4
Flange with insulating gasket
5
Air damper adjustment screw
3.3

Burner equipment

Flange with insulating gasket .............................................. No. 1
Screws for flange to be fixed to boiler ................................. No. 4
Screw and nuts for flange.................................................... No. 1
Flexible oil pipes with nipples .............................................. No. 1
Hexagonal key..................................................................... No. 1
Screw of by-pass pump ....................................................... No. 1
Plastic air cover ................................................................... No. 1
4 pin plug............................................................................. No. 1
Technical description of the burner
Kerosene, viscosity 1.6 – 6 mm
Kerosene, maximum pressure 10 bar (145 psi)
10
5
4
D4138
7
GB
RDB2.2 Firebird 12/18
1.0 - 1.5 kg/h
12 - 18 kW
2
/s at 20 °C
Single phase, ~ 50Hz 230 V ± 10%
Run current 0.85 A – 2700 rpm – 283 rad/s
4.5 mF
Secondary 8 kV – 25 mA
0.16 kW
1
6
Snorkel (BF)
7
Pump pressure adjustment screw
8
Pressure gauge port
9
Flame sensor
10
Blast tube
The hoses supplied with this burner set for
Kerosene use are not suitable for use with Gas oil
containing a Bio blend.
WARNING
Please refer to the spare part list for the specific
hoses suitable for bio fuel use.
In case of use with gas oil containing up to 10%
Bio blend, it will be essential to use flexible oil
lines suitable for bio fuel use.
Please contact Riello for further information.
(Hi = 11.97 kWh/kg)
Tab. A
6
2
7
8
Fig. 1
20074517