3. Disassembly and Reassembly
3-12 Removing Assy-Partition Switch
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range. Replace all panels before operating range. Failure to do so
can result in death or electrical shock.
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts. Sharp edges may
be present, and you can cut yourself if you are not careful.
Parts
Assy Partition
Switch
* Reassembly of All part is the reverse order of disassembly.
Explanation Photo
20
Explanation
1. Turn off the electrical supply going to the range and
pull the range from its mounting location.
2. Remove Cover-Back Main Wire and disconnect the
wires from Assy-Partiton Switch.
3. Unscrew the two screws securing the Assy-Partition
Switch.
4. Replace the Assy-Partition Switch.