USER'S GUIDE
ASCH SERIES
PORTABLE HEATER
WARNING
This product is designed and approved for use under normal, dry conditions. It is not intended for use or storage within damp and/or dusty conditions. It
should not be exposed to flammable liquids, combustible materials, corrosive, abrasive, chemical and/or explosive products such as, but not limited to, paint,
gasoline, chlorine, cleaning products, sawdust, etc.
When choosing a heater, assure that it is suitable to the application. Should your application possess any of the above-mentioned conditions, then your
product should be designed specifically to operate under those conditions. We highly recommend inquiring with your insurance company, CSA and UL or any
other recognized equivalent, to assist you in your product selection. We encourage you to consult your local electrical and building codes.
Stelpro Design inc. does not warrant their products should they be used under any condition to which their design is not intended, nor shall they be held
responsible for any incident arising as a result of improper use.
Please ensure that the plug of the unit is not impaired (color changes, rust, distorsion, etc.). It is important to inspect the plug and the electrical outlet at least
once a year, or once a month if they are used on a construction site. A damaged plug or outlet could cause a fire.
It is the user's responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on and inside air vents. Accumulated dirt can
lead to a component malfunction. It may cause a fire hazard if not installed and maintained in accordance with these instructions.Read all instructions before
using this heater. Save these instructions. When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following. If these instructions are not followed, the warranty will be considered null and void and the manufacturer
deems no further responsibility for this product.
This unit must be used in accordance with the electrical and building codes effective in your region.
Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the unit's nameplate.
Connect to properly grounded outlets only. (This item may be omitted if the heater is not provided with a grounding type attachment plug.)
Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit. To disconnect heater, turn controls to off, then remove plug
from outlet.
For further information or to consult this guide online, please visit our website at www.stelpro.com
REPLACEMENT COMPONENT LIST INCLUDED
IMPORTANT INSTRUCTIONS
DATE:
DESSINATEUR
/ DRAFTER:
DESSIN TECHNIQUE / TECHNICAL DRAWING
APPAREIL
2
4
0 /
3
2 /
0
1
1
/ UNIT:
MIS À JOUR
A. DESMARAIS
UPDATED:
This unit
complies with
the CSA
standards
A
P
C
H
INSASCH1116
Need help?
Do you have a question about the ASCH Series and is the answer not in the manual?
Questions and answers