Possible Cause - Ryobi RA-AG100-B Quick Start Manual

Air angle grinder
Table of Contents

Advertisement

chamber. Severe operating conditions may require
more frequent lubrication.
pROBLEM: Tool runs slowly. Air flows slightly from
exhaust.
pOssIBLE cAusEs
■ Motor parts are jammed with dirt particles.
■ Air regulator is in closed position.
■ Air flow is blocked by dirt.
REMEDIEs
■ Check air inlet filter for blockage.
■ Pour air tool lubricating oil into air inlet as per
instructions.
■ Operate tool in short bursts quickly reversing rotation
back and forth where applicable.
■ Repeat above as needed.
pROBLEM: tool will not run. Air flows freely from
exhaust.

pOssIBLE cAusE

One or more motor vanes are stuck due to material
build up.
REMEDIEs
■ Pour air tool lubricating oil into air inlet.
■ Operate tool in short bursts of forward and/or reverse
rotation where applicable.
■ Tap motor housing gently with a plastic mallet.
■ Disconnect the air supply. Free the motor by rotating
drive shank manually where applicable.
■ If the product remains jammed, return to the service
centre.
pROBLEM: tool will not shut off.
pOssIBLE cAusE
'O' rings throttle valve is dislodged from seat inlet
valve.
REMEDy
Replace the 'O' ring.
NOtE: Repairs should be carried out by a qualified
person.
6

Advertisement

Table of Contents
loading

Table of Contents