Annual (At Fall); User's Troubleshooting - Venmar A180H75RT Series User's And Installer's Manual

Table of Contents

Advertisement

Available languages

Available languages

9. MAINTENANCE (
9.2 A
(
f
)
nnuAl
AT
All
1.
Repeat steps 1 to 6 from the previous section and continue with the following steps:
Handle the recovery core with care.
2.
Clean the recovery core:
Remove the core.
Let it soak in a mixture of cold or lukewarm water
and mild soap (dishwashing liquid).
Rinse thoroughly.
Shake the core to remove excess water and let it dry.
3.
Clean the blower assemblies. Do not disassemble the blower assemblies.
4.
Remove the dust using a vacuum cleaner with a soft brush attachment.
5.
Reassemble the components.
6.
Reconnect power supply.

10. USER'S TROUBLESHOOTING

If the unit does not work properly, reset the unit by unplugging it for one minute then replug it.
Contact customer service at 1-800-567-3855 for any unresolved issue.
p
roblem
1. Nothing works.
2. Noisy unit.
3. Condensation inside windows under
cold weather conditions.
4. Humidity inside under hot/humid
weather conditions.
5. Air too dry.
6. Air too cold at the air supply register. • Make sure the outdoor hoods are not blocked.
'
)
Cont
d
CAUTION
Hrv m
odels
t
ry thiS
• See if the unit is plugged in.
• See if the unit is receiving power from the house circuit breaker or fuse.
• Clean the unit (see Section 9). If the problem is not solved, contact your installer.
• Operate the unit at MAX speed during activities generating excess humidity
(family gatherings, extra cooking, etc.).
• Leave curtains half-open to allow air circulation.
• Store all firewood in a closed room with a dehumidifier or in a well ventilated
room, or store the wood outdoors.
• Keep the temperature in your house above 18 °C
• Operate the unit in MIN speed.
• Temporarily switch to INT mode (if available).
• Use a dehumidifier.
• Operate the unit at MIN speed.
• Temporarily switch to INT mode (if available).
• Temporarily use a humidifier.
• Operate the unit at MIN speed.
• Install a duct heater (contact your installer).
Remove the dust on the core using a vacuum cleaner
and a soft brush attachment.
CAUTION: DO NOT SOAK THE ENERGY RECOVERY
CORE IN WATER
24
VD0494
erv m
odels
64°F).
(

Advertisement

Table of Contents
loading

Table of Contents