Download Print this page

Trouble Shooting - Osram BY-M03B User Manual

25*4in1 matrix moving head zoom

Advertisement

5. When fixtures signal input select Art-Net or DMX & Art-Net, means selected Art-Net
controller to control fixtures. But Art-Net controller also need set the same IP address, IP
MARK as fixtures.
Setting via menu
Information
Ethernet IP
IP Address
IP MARK
→ select search fixture's
,
information.

6. Trouble shooting

Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on
PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor's drive IC on the PCB might be out of condition.