Osram ADB Stagelight LEXPERT PROFILE L Instruction Manual
Osram ADB Stagelight LEXPERT PROFILE L Instruction Manual

Osram ADB Stagelight LEXPERT PROFILE L Instruction Manual

Hide thumbs Also See for ADB Stagelight LEXPERT PROFILE L:

Advertisement

Quick Links

INSTRUCTION MANUAL
LEXPERT PROFILE L
Zoom 15-30
Zoom 25-50
AG2300E41200 - AG2500E41200
Congratulations on choosing a ADB product! We thank you for your custom.
Please note that this product, as all the others in the rich ADB range, has been designed and made with total quality to ensure
excellent performance and best meet your expectations and requirements.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADB Stagelight LEXPERT PROFILE L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Osram ADB Stagelight LEXPERT PROFILE L

  • Page 1 INSTRUCTION MANUAL LEXPERT PROFILE L Zoom 15-30 Zoom 25-50 AG2300E41200 - AG2500E41200 Congratulations on choosing a ADB product! We thank you for your custom. Please note that this product, as all the others in the rich ADB range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements.
  • Page 2: Table Of Contents

    INDEX SAFETY INSTRUCTION TECHNICAL SPECIFICATIONS THE UNIT CONSTRUCTION INSTALLATION POWER CONTROL PANEL MAIN FUNCTION DMX Address Setting HOW TO CONTROL THE UNIT DMX Configuration DMX Connection TROUBLESHOOTING FIXTURE CLEANING LEXPERT PROFILE L...
  • Page 3: Safety Instruction

    1. SAFETY INFORMATION How to get your SAFETY INSTRUCTIONS in multilingual version. You may always download the multilingual Safety Instruction manual for this ADB product from: Rif: FIS00X - Safety Information LEXPERT PROFILE L www.adbstagelight.com Come ottenere le INFORMAZIONI DI SICUREZZA nella versione multilingue.
  • Page 4 Warning: Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. • Unpack and check carefully there is no transportation damage before using the unit. •...
  • Page 5: Technical Specifications

    2. TECHNICAL SPECIFICATIONS • DMX Control: 5 Channel Modes: Mode 1: 8 bit dimming Mode 2: 8 bit dimming + Strobe Mode 3: 16 bit dimming Mode 4: 16 bit dimming + Strobe Mode 5: 16 bit dimming + Strobe + Control •...
  • Page 6: The Unit Construction

    3. THE UNIT CONSTRUCTION 1. Lens Module 2. Clip for Gel Holder 3. Bracket 4. Main Body 5. Godo Slot 4. INSTALLATION Screw Two triangles signs Loosen two screws on two sides of Main Body (MB), rotate the zoom as the arrow and align it with two triangles signs, put the zoom into the MB - Fig. 3 LEXPERT PROFILE L...
  • Page 7: Installation

    Screw Two triangles Two triangles signs signs Rotate the zoom as the arrow shown, align it with two triangles sign, and tighten the two screws on two sides of the unit to fix the zoom - Fig. 4 5. POWER The power requirements are as follows: Voltage: AC100-240V, 50/60Hz Power: 345W...
  • Page 8: Power

    6. CONTROL PANEL 1. Display: To show the various menus and the selected functions. 2. LED: Master Mode MASTER Slave Mode SLAVE DMX input present 3. Dimmer Adjust Knob: Adjust the lightness for the unit 4. Button: To select the programming functions MENU To go backward in the selected functions DOWN...
  • Page 9: Main Function

    7. MAIN FUNCTION To select any functions, press the MENU button until the required function is showing on the display. Select the function by pressing the ENTER button and the display will blink. Use the DOWN and UP button to change the mode. Once the required mode has been selected, press the ENTER button to setup to go back to the functions without any changes press the MENU button again.
  • Page 10 LEXPERT PROFILE L...
  • Page 11 DMX Address To select the DMX Address, press the ENTER button to show DMX ADDRESS on the display. Use the DOWN/UP button to adjust the address from 1 to 512. Once the address has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
  • Page 12 To select the Network, press the ENTER button to show Network on the display. Use the DOWN/UP button to select the IP or Mask. Once the mode Network has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
  • Page 13 Strobe or Control. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode. To select the Fan Speed, press the ENTER button to show Fan Speed on the display.
  • Page 14: Dmx Configuration

    To select the Slave Mode, press the ENTER button to show Slave Mode on the display. Use the DOWN/UP button to select the Master or Slave. Once Slave Mode the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
  • Page 15 2 Channel Mode CHANNEL VALUE FUNCTION DIMMER 0 – 255 Close Open 0% ~ 100% Strobe 000-00 9 Open 010-057 Strobe (variable speed) 058-059 Open 060-108 Pulse Slow closing fast opening variable speed 109 -110 Open 111 -159 Pulse fast closing slow opening variable speed 160 -161 Open 162 -207...
  • Page 16 4 Channel Mode CHANNEL VALUE FUNCTION DIMMER 0 – 255 Close Open 0% ~ 100% Dimmer Fine 0 – 255 0% ~ 100% Strobe 000 - 009 Open 010-057 Strobe (variable speed) 058-059 Open 060-108 Pulse Slow closing fast opening variable speed 109 -110 Open 111 -159...
  • Page 17 5 Channel Mode CHANNEL VALUE FUNCTION DIMMER 0 – 255 Close Open 0% ~ 100% Dimmer Fine 0 – 255 0% ~ 100% Strobe 000 - 009 Open 010-057 Strobe (variable speed) 058-059 Open 060-108 Pulse Slow closing fast opening variable speed 109 -110 Open 111 -159...
  • Page 18: Dmx Connection

    8.3 DMX Connection DMX OUT DMX Controller COMMON DMX - DMX + DMX INPUT DMX OUTPUT Not Used Not Used 1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5- pin XLR-plug and plug it in the DMX-output of the last unit.
  • Page 19: Troubleshooting

    9. TROUBLESHOOTING Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: 1. Check the connection of power and main fuse. A. The unit does not work, no light and the fan does not work 1.
  • Page 20 - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311 - Fax +39-035-301876 - www.claypaky.it Clay Paky S.p.A.

Table of Contents