2-3. Remote 14 Receptacle RC14 Information and Connections

2

2-4. Remote 14 Socket Information

Remote Contactor
Remote Output Control
Power Source Limit
Remote Metering
3
Socket
+24 volts dc.
A
Contact closure to A completes 24 volts dc contactor control circuit.
B
Command reference; +10 volts dc.
C
Control circuit common.
D
Input command signal (potentiometer wiper or 0 to +10 volts dc).
E
Not used.
G
Absence of internal contact closure between F and J signals power source failure to remote
F, J
control device.
Coil loss compensation value.
H
H
Actual frequency output signal (1 volt/10 kHz).
I
I
Average power output signal (1 volt/5 kW).
L
Voltage output signal RMS (1 volt/100 volts).
M
Current output signal RMS (1 volt/100 amperes).
N
Chassis common.
K
1
4
A
J
5
K
I
B
C L N
H
M
D
G
F
E
sb7.1* 3/93 - Ref. S-0004-A / Ref. S-0750 / Ref. ST-801 826-C
Socket Information
1
Front Panel
2
Plug
3
Threaded Collar
4
Keyway
5
Remote 14 Receptacle RC14
(See Section 2-4)
To connect to receptacle, align key-
way, insert plug, and tighten
threaded collar.
OM-184 227 Page 7