Initiating and Terminating Tests from the Modem's Front Panel
To initiate a test from the modem's front panel:
1) Press
2) Press
3) Press
4) Press
To terminate a test from the modem's front panel:
1) Press
2) Press

Synchronous Data Compression (SDC) Testing

When performing diagnostic tests in SDC mode, note the following:
• All tests are supported
• When initiating the following "online" tests:
— Remote digital loopback
— Remote digital loopback pattern
— Data mode pattern
— Local digital loopback
during SDC connection, the modem falls back to Direct mode (Mode=Direct,
*
AT
SM) to run the test. If the modem is set for internal timing
(Clock=Internal, AT&X) the DTE clock is changed to match the DCE rate. If
the modem is set for external timing (Clock=External, AT&X), the clock rate
provided may not match the DCE rate and the test will not function. (Set
Clock=Internal temporarily to complete testing, and then reset to External.)
• To test the synchronous data path's integrity while running loopback tests, set
the modem for one of the asynchronous buffered modes (Mode=Normal,
Reliable, Auto Reliable, or Speed Auto Reliable).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
until you reach the TEST OPTS category.
until you reach Test=End Test.
until Test=LAL (for example)
to start the test.
until Test=End Test.
to stop the test.
Troubleshooting Guide 6-11