Spectra Logic AIT-3 Supplementary Manual

Spectra logic ait-3: supplementary guide
Hide thumbs Also See for AIT-3:

Advertisement

Quick Links

Using Degaussed AIT-3 Tapes in Gator Libraries
1. Manually load the Degauss firmware tape—this will take a couple of minutes. Once
the firmware upload is finished, the tape will eject itself. Remove the firmware tape
from the library.
Note:
The inquiry string will not show the new firmware revision until
drive is power cycled or a configuration save is issued.
2. Leave the drive empty and go to the front panel of the Gator Library. Navigate to
the Configuration screen, then to the Drives screen. Choose the desired drive and
select Edit. In this screen, there will be a small icon representing the DIP switches
for both drives (Figure 1).
Note:
Drives are configured as drive pairs. This setting will affect the DIP
switch settings for both drives.
3. Select the Switches icon to enter the DIP switch screen.
4. Once in this screen, toggle the first switch on. This action should set the numerical
representation to 1.
5. Save all changes and let the drives finish configuration.
6. At this point, you should be able to read and write to Degauss Media.
Figure 1 The edit drives switches window.
1

Advertisement

loading

Summary of Contents for Spectra Logic AIT-3

  • Page 1 Using Degaussed AIT-3 Tapes in Gator Libraries 1. Manually load the Degauss firmware tape—this will take a couple of minutes. Once the firmware upload is finished, the tape will eject itself. Remove the firmware tape from the library. Note: The inquiry string will not show the new firmware revision until drive is power cycled or a configuration save is issued.
  • Page 2 Additional notes: • Note: Tapes in a drive without the Degauss Firmware will report error: CRC CHECK FAILED. • Drives only retain DIP switch settings until they are power cycled. Any drive that is re-initialized will no longer be capable of writing to Degaussed media and will need the DIP switches reset.