Securing The Burner To The Boiler; Hinge Installation; Positioning The Probe - Electrode - Riello 40 GS20 TL Installation, Use And Maintenance Instructions

Forced draught gas burner
Table of Contents

Advertisement

5.6

Securing the burner to the boiler

Provide an adequate lifting system of the burner.
Boiler door must have a max. thickness of 100
mm, refractory lining included.
WARNING
5.6.1

Hinge installation

Install the hinge 4), supplied as standard, as shown in Fig. 9.
S7393
5.7

Positioning the probe - electrode

Respect the positions shown in Fig. 11.
WARNING
~
Probe
D5104
4
47 mm
Installation
 Separate the combustion head assembly from the burner
body by removing nut 1) and removing the group A)(Fig. 10).
 Fix the group B)(Fig. 10) to the boiler plate 2), inserting the
supplied insulating gasket 3).
The seal between burner and boiler must be
airtight.
WARNING
A
Fig. 9
Electrode
Diffuser
2.0 - 3.0 mm
15
GB
1
Probe
Electrode
3.7
=
3
2
D5096
B
Fig. 10
Fig. 11
20063701