Riello 40 GS20 TL Installation, Use And Maintenance Instructions page 32

Forced draught gas burner
Table of Contents

Advertisement

Signal
Problem
Ignition with pulsations
Burner stops with air
damper open
If start-up problems persist even after the above-
mentioned interventions, first replace the control
box, check that there are no short-circuits in the
WARNING
lines of the motor, the gas solenoid valves, the ig-
nition transformer and the external signals.
20063701
Faults - Possible causes - Solutions
Possible cause
Poorly adjusted head
Ignition electrode incorrectly adjusted
Incorrectly adjusted fan air damper: too much air Adjust
Output during ignition phase is too high
Defective air damper opening motor
30
GB
Recommended remedy
Adjust
Adjust it
Reduce
Replace
Tab. O