Recall Function; Control Panel Locking; Operating Time - Kuppersbusch EKE8342.1ED Instructions For Use And Installation

Table of Contents

Advertisement

Recall Function

After switching off the hob (
• cooking stages of all cooking zones (power)
• minutes and seconds of programmed cooking zone-related timers
• Heat up function
The recall procedure is following:
• Press the key [
• Then press the key [
The precedent settings are activated.

Control panel locking

To avoid modifying a setting of cooking zones, in particular with within the framework of
cleaning the control panel can be locked (with exception to the On/Off key [
Locking
Action
To start
Hob locking
Unlocking
Action
To start
Unlocking the hob

Operating time

Each cooking zone is equipped with an operating time limitation: the cooking zone is automatically
switched off after a certain time without any change of settings. This time is varying according to
the selected power level as described in the table below.
), it is possible to recall the last settings.
]
] within 6 seconds
Control panel
press the key [
Hold a finger on the [
and press 3 times on the [
Control panel
press the key [
Hold a finger on the [
and press 3 times on the [
Power level
1
2
3
4
5
6
7
8
9
]
]
]
]
Max operating time
(hours)
6
6
5
5
4
1,5
1,5
1,5
1,5
25
]).
Display
[ 0 ] or [ H ]
]
[ L ]
Display
[ L ]
]
[ 0 ] or [ H ]

Advertisement

Table of Contents
loading

Table of Contents