8.1 Set Alarm Input

Alarm signal from the external device triggers the corresponding actions of the current device.
Before You Start
Make sure the external alarm device is connected. See Quick Start Guide for cable connection.
Steps
1. Go to Configuration → Event → Basic Event → Alarm Input .
2. Check Enable Alarm Input Handling.
3. Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
5. Click Copy to... to copy the settings to other alarm input channels.
6. Click Save.

8.2 Set Exception Alarm

Exception such as network disconnection can trigger the device to take corresponding action.
Steps
1. Go to Configuration → Event → Basic Event → Exception .
2. Select Exception Type.
HDD Full
HDD Error
Network Disconnected The device is offline.
IP Address Conflicted
Illegal Login
3. Refer to Linkage Method Settings for setting linkage method.
4. Click Save.

Chapter 8 Event and Alarm

The HDD storage is full.
Error occurs in HDD.
The IP address of current device is same as that of other device in
the network.
Incorrect user name or password is entered.