4 MONITORING SPECIFICATION
(3) Communication overview
Always write
reqister
command
Always write
request
command
4 - 28
When always writing data in the remote register to the GOT internal device
GD100, 110 and 120.
PLC CPU
1)
TO
3)
TO
1) Store the always write register command data in the master station's remote
register (RWw).
2) Turn on the GOT request flag, and store the command data in the GOT
remote register (RWw).
(Command execution)
The GOT complete flag turns on when the command processing is complete.
3) Store the always write data in the master station's remote register (RWw).
4) Always write the write data to the GOT internal device GD100, 200, and 300
by turning on the GOT always write request flag.
Get other manuals https://www.bkmanuals.com
Master station
remote register
RWw0
0803
H
RWw1
0064
H
RWw2
00C8
H
RWw3
012C
H
RWw0
1234
H
RWw1
0E54
H
RWw2
0066
H
GOT always write
request flag
4)
MELSEC-GOT
GOT
remote register
RWw0
0803
H
2)
RWw1
0064
H
RWw2
00C8
H
RWw3
012C
H
RWw0
1234
H
4)
RWw1
0E54
H
RWw2
0066
H
4)
GD100
1234
H
GD200
0E54
H
GD300
0066
H
GOT internal device
4 - 28