1.6
DESIGN AND GENERAL HEATER DIMENSIONS
The bivalent source consists of an electrical heating element with a connecting thread G 2" (Figure 1). A safety
thermostat and a connection terminal block are placed under the wiring plastic cover.
Legend:
1 - bivalent source steel casing
2 - thermal insulation
3 - cover with wiring
TYPE
TJ 2" EHP 6 kW
TJ 2" EHP 9 kW
OUTPUT
CONNECTION
kW
2 - 6
3 PE-N AC 3x 230 V/50 Hz
3 - 9
3 PE-N AC 3x 230 V/50 Hz
Figure 1
RECOMMENDED
CIRCUIT BREAKER
VALUE
3x 16
3x 16
Table 1
ELECTR.
PROTECTION
A
IP 44
IP 44
- 5 -