Nibe SMO 20 CONTROL MODULE Manual
Nibe SMO 20 CONTROL MODULE Manual

Nibe SMO 20 CONTROL MODULE Manual

Modern, simple control module that, together with a nibe air/water heat pump
Hide thumbs Also See for SMO 20 CONTROL MODULE:

Advertisement

NIBE™
SMO 20
CONTROL MODULE
BE IN CONTROL.
• Simple installation.
• Enables optimised control of the climate unit.
• Control the climate unit using degree minute calculation.
• Clear display of the heat pump's and heating system's es-
sential temperatures.
• SMO 20 has automatic legionella control.
• With a height of only 1500 mm, VPB 200/70, together
with SMO 20 and any NIBE outdoor air heat pump F2030
or F2040, makes an excellent combination in the event of
low ceilings.
• NIBE UplinkTM in combination with the internet gives a
quick overview and the present status of the installation
and comfort in the home regardless of the location of the
user.
NIBE SMO 20
SMO 20 is a modern, simple control module that, together
with a NIBE air/water heat pump, a water heater and an ex-
tra step-controlled addition, creates a complete installation.
Outdoor sensor, room sensor and three temperature sensors
are included. F2040/F2300 works with floating condensing
against the heating system and prioritises hot water charging
via the reversing valve.

Advertisement

Table of Contents
loading

Summary of Contents for Nibe SMO 20 CONTROL MODULE

  • Page 1 NIBE SMO 20 SMO 20 is a modern, simple control module that, together with a NIBE air/water heat pump, a water heater and an ex- tra step-controlled addition, creates a complete installation. Outdoor sensor, room sensor and three temperature sensors are included.
  • Page 2: Principle Of Operation

    SMO 20 can be connected together with other products from Installations with SMO 20 can produce heating and hot water. NIBE in several different ways, some of which are shown below On cold days of the year when the access to energy from the (accessories may be required).
  • Page 3 GOOD TO KNOW ABOUT NIBE ™ SMO 20 System diagram for a compatible air/water heat pump to- gether with SMO 20 and electric heater after reversing valve for hot water (floating condensing) -EB1 -EB1 -KA1 -AA25 -CP5 -BT25 -GP10 -BT71...
  • Page 4 GOOD TO KNOW ABOUT NIBE ™ SMO 20 Equipment SMO 20 4 NIBE SMO 20...
  • Page 5 GOOD TO KNOW ABOUT NIBE SMO 20 ™ List of components Electrical components AA 2 Base card AA 4 Display unit AA 7 Extra relay circuit board FA 1 Miniature circuit-breaker Terminal block, incoming electrical supply Terminal block, control signal circulation pump,...
  • Page 6 GOOD TO KNOW ABOUT NIBE ™ SMO 20 Dimensions SMO 20 Supplied components Outdoor sensor Temperature sensor Heating pipe paste Cable tie Aluminium tape Insulation tape 6 NIBE SMO 20...
  • Page 7: System Solutions

    CPD 10-25/60 ELK 26 UKV 300 UKV 500 F2040 – 16 kW VPB 500 VPB 750-2 VPB 1000 F2300 – 14 kW VST 20 VPA 450/300 VPB 750-2 F2300 – 20 kW VPAS 300/450 VPB 1000 NIBE SMO 20 7...
  • Page 8: Installation

    1.9.1. To reach a high level of heating comfort during the heating phase, the external circulation pump circulates the hot water in the heat- ing system even when the domestic hot water output is high. 8 NIBE SMO 20...
  • Page 9 • Contact for activation of “external adjustment” Compatible NIBE air/water heat pumps must be equipped with a control card that has at least the software version given in the following list. The control card version is displayed in the heat Possible selection for AUX outputs pump's display (if applicable) upon start-up.
  • Page 10: Display Unit

    The back button is used to: Display HOT WATER • go back to the previous menu. MY SYSTEM Status lamp • change a setting that has not been confirmed. OK button Back button Control knob Switch SMO 20 10 NIBE SMO 20...
  • Page 11: Menu System

    The start guide ensures that the start-up is carried out correctly and cannot be bypassed. The start guide can be started later in menu 5.7. If the start guide is left on this page it closes automatically in 58 min NIBE SMO 20 11...
  • Page 12: Technical Specifications

    TECHNICAL SPECIFICATIONS IP 24 SMO 20 Width (mm) Height (mm) Depth (mm) Weight, (without packaging and enclosed components) (kg) Enclosure class IP21 Max number air/water heat pumps Max number of sensors Max number of charge pumps Max number of circulation pumps/climate systems Mains voltage 230 V 2~ 50 Hz Max.
  • Page 13 Max recommended charge VPB 1000 power, 17 kW 8 kW / 12 kW / 16 kW VST20 F2300 Reversing valve, Ø 35 mm, com- 14 kW / 20 kW pression ring Max recommended charge power, 40 kW NIBE SMO 20 13...
  • Page 14 SS-EN ISO 14001:2004 Box 14 285 21 Markaryd This brochure is a publication from NIBE. All product illustrations, facts and specifications are based on current information at the time of the publication’s approval. NIBE makes reservations SWEDEN Tel. +46 433 - 73 000 for any factual or printing errors in this brochure.

Table of Contents