Onboard Charger (Optional)
Circuit Breaker must be off before unplugging
batteries or connecting the charger AC plug to a
wall outlet.
Le disjoncteur doit être coupé avant de débrancher
les batteries ou de connecter la fiche CA du
chargeur à une prise murale.

Battery Charger Programming

For machines equipped with optional on-board charger.
When replacing batteries, charger programming
changes may be required. If replacing batteries with
same type, (e.g. maintenance free batteries with main-
tenance free) no programming is required. If replacing
batteries with different type (e.g.maintenance free with
wet cell), programming changes are required. Failure to
make programming changes may lead to reduced
battery life.
1. Remove four nuts from charger mounting bracket.
Lift charger out of cover.
2. Peel back label on charger to access DIP switches.
3. Change switches to correct battery type.
DIP DIP DIP
1
2
OFF ON ON
LEAD ACID
ON OFF OFF
DISCOVER AGM
DIP
DIP DIP DIP DIP
3
4
5
6
7
ON
OFF ON ON OFF
OFF
OFF ON ON OFF
8.641-374.0 operator's manual - chariot 3 - cv86/1 rs bp
4. Replace charger label and lower charger back into
cover. Tighten four nuts to secure charger to
mounting bracket.