Chapter 2 Receipt of Your Vogt Ice Machine

Inspection

As soon as you receive your machine, inspect it for any damage. If damage is suspected, note it on the shipper's papers
(i.e., the trucker's Bill of Lading). Immediately make a separate written request for inspection by the freight line's agent.
Any repair work or alteration to the machine without the permission of Vogt Ice, LLC can void the machine's warranty.
The machine was shipped with a full tank of ISO 32 hydraulic fluid. Visually check all lines for mechanical damage. If a
leak is suspected, contact the Vogt Ice, LLC service department to obtain authorization for repair.
The machine also contains a series of limit switches, shown in the P&ID in Section 4. Visually check that the switches are
intact and were not damaged during shipping. If damage is suspected, contact the Vogt Ice, LLC service department to
obtain authorization for repair.

Safety Valves

This machine has been provided with pressure safety valves that are installed in the hydraulic system to prevent over-
pressurization. In the event that these valves open, the excess fluid pressure will be vented into the hydraulic reservoir,
which is constantly at atmospheric pressure. These safety valves have been preset by the factory. Do not adjust them.

Machine Room

The machine must be located inside of a suitable building, fully protected from outside elements. It was designed to be
operated between 38°F and 100°F. Heat from other sources (sunlight, furnaces, condensers, etc.) and unusual air
currents may affect the operation or life cycle of the machine and should be avoided. It is not capable of operating in
cold rooms, freezers, or other locations where the ambient temperature can drop below 38°F. Ambient temperatures in
excess of 100°F can be detrimental to the hydraulic system, as it may be unable to cool the oil sufficiently.
Electrical components are rated NEMA 1, and should not be located in a hazardous area or sprayed with water. The
machine should be installed on a drainable drip pan or in an area where water will not stand, but readily drain away
from the machine. See Space Diagrams, Figure 3 thru Figure 5, for clearances and utility connections. Ambient
temperatures in excess of 100°F can be detrimental to the electrical devices and control equipment.
Only service personnel experienced in hydraulic system operation
and qualified to work with high voltage electrical equipment
should be allowed to install or to work on this machine
The approximate weight of the machine is 2400 lbs.
Use only the appropriate equipment with adequate
loading capacity to move and install the machine.
!